Date |
Text |
2016-07-05 12:06:29 | BUILDING PLAN REVIEW |
| 2014 FLORIDA BUILDING CODE |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| BUILDING PLANS EXAMINER ? PX3169 |
| CONSTRUCTION SERVICES DIVISION |
| DEVELOPMENT SERVICES DEPARTMENT |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| ACTION: DENIED |
| DATE: 7/5/16 |
| |
| 1. REPAIR TO ROOF JOIST MAY REQUIRE A ROOFING PERMIT. |
| IF ROOFING IS REPAIRED, PROVIDE PRODUCT APPROVALS FOR |
| ROOF SYSTEM. |
| 2. PLAN IS NOT CLEAR WHAT IS EXISTING AND WHAT WILL BE |
| REPLACED. ARE ALL ELEMENTS OF TYP. WALL SECTION TO BE |
| REPLACED? CONCRETE SLAB? (MISSING RE-INFORCING) 2X4 |
| BOTTOM PLATE? SPACING OF 1/2" X 5" ANCH. BOLTS? PRODUCT |
| TO BE USED FOR SUB-FLOORING? ROOF SHEATHING? WIND LOAD |
| ENGINEERING AND FASTENER SCHEDULE. |
| 3. WALL SECTION SHOWS 2X4 BOTTOM PLATE, 2X4 TOP PLATE |
| AND 2X6 WALL STUDS. PLEASE CLARIFY. |
| 4. PROVIDE FLOOR PLAN INDICATING THE LOCATION OF |
| REPAIRS IN STRUCTURE. |
| 5, PROVIDE SPAN OF NEW 2X6 FLOOR JOISTS. |
| 6. PROVIDE DETAIL FOR EXTERIOR WALL SYSTEM. |
| 7. CANNOT DETERMINE IF VALUE IS ADEQUATE. NEED |
| ADDITIONAL INFORMATION. |
| 8. PROVIDE SCOPE OF WORK CLEARLY IDENTIFYING WORK TO BE |
| PERFORMED. |
| 9. PROTECTION OF WOOD FLOOR JOIST PER R317.1 IF CRAWL |
| SPACE IS LESS THAN 18". |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| REVIEWED SHEETS DETACHED. |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE |
| DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH |
| INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES |
| SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE |
| TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE |
| FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE |
| DESIGN. (SEE ALSO SECTION 107.3.5). |
| |
| |