Plan Review Notes
Plan Review Notes For Permit 16061515
Permit Number 16061515
Review Stop B
Sequence Number 1
Notes
Date Text
2016-06-30 06:57:02****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 5TH EDITION
  
 1. PROVIDE A LEGIBLE PLAN TO PROVIDE THE FOLLOWING
 INFORMATION:
  
 TOTAL NUMBER OF PARKING SPACES (PLAN STATES THERE ARE
 230 TOTAL, BUT AERIALS SHOW OVER 260)
 NUMBER OF ACCESSIBLE SPACES
 LOCATION OF ACCESSIBLE ENTRANCES
 LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES
 SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY
 ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE
 ENTRANCE
  
 SEE FBC 2010 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2
 (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE
 ROUTE).
  
 YOU MAY FIND THE FOLLOWING DOCUMENT USEFUL,
 PARTICULARLY THE INTRODUCTION: "WHEN A BUSINESS
 RESTRIPES A PARKING LOT, IT MUST PROVIDE ACCESSIBLE
 PARKING SPACES AS REQUIRED BY THE ADA STANDARDS FOR
 ACCESSIBLE DESIGN."
  
 HTTP://WWW.ADA.GOV/RESTRIPE.HTM
  
 2. FBC 2010 ACCESSIBILITY ADVISORY 502.3, WHERE THE
 ACCESSIBLE ROUTE MUST CROSS VEHICULAR TRAFFIC LANES,
 MARKED CROSSINGS ENHANCE PEDESTRIAN SAFETY; PLEASE
 INDICATE LOCATION ON PLAN.
  
 3. THE INDIVIDUAL TAKING RESPONSIBILITY SHALL PROVIDE
 THEIR PRINTED NAME AND SIGNATURE ON THE PLAN, FBC 107.
  
 4. FBC 2014 ACCESSIBILITY 208.2.1, THE FOLLOWING USES
 HAVE ADDITIONAL PARKING REQUIREMENTS:
  
 HOSPITAL OUTPATIENT FACILITES
 REHABILITATION FACILITIES
 OUTPATIENT PHYSICAL THERAPY FACILITIES
  
 PLAN IS TO EITHER SHOW LOCATION OF TENANTS WITH ANY OF
 THE ABOVE USES OR PLAN IS TO INCLUDE A STATEMENT WHICH
 STATES THAT NONE OF THE ABOVE USES (HOSPITAL OUTPATIENT
 FACILITIES, REHABILITATION FACILITIES, OUTPATIENT
 PHYSICAL THERAPY FACILITIES) ARE AT THIS LOCATION.
  
 5. THE PLAN PROVIDED SHOWS TWO ACCESSIBLE SPACES WHICH
 ARE NOT ADJACENT TO THE BUILDING THEY SERVE, WHICH
 APPEAR TO BE THE "GENERAL REPAIR AND MAINTENANCE"
 BUILDING; BOTH WOULD BE COMPELLED TO WALK BEHIND PARKED
 CARS TO ACCESS THE BUILDING. HOWEVER, AERIALS SHOW
 THESE TWO SPACES AS SERVING THE "INLINE RETAIL &
 QUALITY RESTAURANT" BUILDING. THIS IS A VERY LONG ROUTE
 TO THIS BUILDING.
  
 AERIALS ALSO SHOW ACCESSIBLE PARKING (NW CORNER)
 SERVING "GENERAL REPAIR AND MAINTENANCE BUILDING"
 FORCING THE USER TO CROSS VEHICULAR TRAFFIC, PASSING
 PARKING ADJACENT TO THAT BUILDING. ACCESSIBLE PARKING
 IS TO BE ON THE SHORTEST SAFELY ACCESSIBLE ROUTE. THE
 PLAN PROVIDED DOES NOT DEPICT ANY PARKING SPACES IN
 THIS AREA. THE PLAN PROVIDED DOES NOT APPEAR TO BE
 ACCURATE. IS APPLICANT PROPOSING TO RECOAT OVER THIS
 AREA AND ELIMINATE THIS PARKING? WERE THEY INCLUDED IN
 THE 230 TOTAL?
  
 LOCATION OF THE 9 ACCESSIBLE SPACES IS NOT CLEAR. PLAN
 SHOWS ONE ACCESSIBLE SPACE ADJACENT TO "GENERAL REPAIR
 AND MAINTENANCE" BUILDING, AERIALS DO NOT SHOW AN
 ACCESSIBLE SPACE IN THIS LOCATION.
  
 NOT ENOUGH INFORMATION HAS BEEN PROVIDED FOR A THOROUGH
 REVIEW. IT IS NOT CLEAR WHETHER THIS REVISION IS TO
 DOCUMENT CHANGES AND AS-BUILT CONDITIONS (WHICH DO NOT
 APPEAR TO BE FBC COMPLIANT) OR TO PROSE ADDITIONAL
 CHANGES.
  