2016-06-30 17:47:55 | RESIDENTIAL (R3) REVISION, SECOND BUILDING REVIEW |
| CHECKLIST. |
| CODE: 2010 FBC. |
| |
| ORIGINAL COMMENT: |
| 1- ORIGINAL APPROVED PLANS DON'T INCLUDE FLAT ROOF |
| SYSTEMS. ENGINEER OF RECORD NEEDS TO REVISE PLANS |
| SPECIFYING THE PROPOSED FLAT ROOF. |
| PROVIDE TWO SIGNED AND SEALED DRAWINGS SHOWING THE |
| REVISION. SEC. R301 OF 2010 FBC-RESIDENTIAL. |
| RESPONSE: |
| A) REVISED DRAWING S-2 SPECIFIES "MODIFIED BITUMEN |
| ROOFING OVER 3/4" PLYWOOD SHEATHING (PER NOA |
| #13-1022.15, 13-0416.05, AND #12-1219.02)". IT IS NOT |
| CLEAR WHAT IS GOING TO BE THE FINISH ROOF MATERIAL. |
| SPECIFIED NOA'S ARE FOR THREE DIFFERENT TYPES OF |
| ASSEMBLIES BY DIFFERENT MANUFACTURER'S. NEED TO PROVIDE |
| THE FOLLOWING: |
| (1)IDENTIFY WHICH NOA IS GOING TO BE USED IN THIS ROOF |
| DECK, THEN PROVIDE COMPLETE NOA (2 COPIES). |
| (2) IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO BE |
| USED. |
| (3) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS (2 |
| COPIES) AS REQUIRED BY GENERAL LIMITATION #7 ON LAST |
| PAGE OF NOA. (NOTE: ASSEMBLIES WITH GENERAL LIMITATION |
| #9 CAN NOT BE USED BECAUSE THEY DON'T ALLOW RAS 117 |
| CALCULATIONS). |
| |
| |
| ORIGINAL COMMENT: |
| 2- FLAT ROOF NOA 11-0601.10 SUBMITTED IS NOT DESIGNED |
| FOR FLAT ROOF. THIS NOA IS AN UNDERLAYMENT FOR PITCHED. |
| ROOFS. REVISE AS REQUIRED. |
| (A) PROVIDE PRODUCT APPROVAL (2 COPIES) FOR FLAT ROOF |
| SYSTEM THAT IS DESIGNED FOR THE ROOF DECK FINISH AS |
| SPECIFIED ON PLANS. |
| FAC 61G20-3.002(33). |
| RESPONSE: |
| SEE COMMENTS FOR ITEM #1 ABOVE AND COORDINATE |
| ACCORDINGLY. |
| |
| (B) CLEARLY IDENTIFY APPROVED ASSEMBLY TO BE USED FROM |
| THE PRODUCT APPROVAL RE-SUBMITTED TO VERIFY COMPLIANCE |
| WITH THE DESIGN PRESSURES OF SEC. R301 OF 2010 |
| FBC-RESIDENTIAL. |
| RESPONSE: |
| SEE COMMENTS FOR ITEM #1 ABOVE AND COORDINATE |
| ACCORDINGLY. |
| |
| |
| (C) IF THE SELECTED ASSEMBLY DOESN'T MEET THE |
| CALCULATED DESIGN PRESSURES, THEN SIGNED AND SEALED RAS |
| 117 CALCULATIONS ARE REQUIRED. SEE PRODUCT APPROVAL |
| SUBMITTED. SEC. R301 OF 2010 FBC-RESIDENTIAL. |
| RESPONSE: |
| SEE COMMENTS FOR ITEM #1 ABOVE AND COORDINATE |
| ACCORDINGLY. |
| |
| |
| (D) ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) FLAT ROOF PRODUCT APPROVAL AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| RESPONSE: |
| SEE COMMENTS FOR ITEM #1 ABOVE AND COORDINATE |
| ACCORDINGLY. |
| |
| ORIGINAL COMMENT: |
| 3- THIS FLAT ROOF SYSTEM WAS NOT PART OF THE APPROVED |
| PLANS. SPECIFY THE ADDITIONAL VALUE FOR THE NEW FLAT |
| ROOF AS REQUIRED BY SEC. 109.3 CITY AMENDMENTS. |
| RESPONSE: |
| THERE ARE MORE REVISION SHOWN ON SHEET S-2. REVISED |
| PLAN SHOW NEW W12X22 STEEL BEAMS INSTEAD OF GLU LAM |
| BEAMS. SPECIFY THE ADDITIONAL VALUE BASED ON THE |
| PROPOSED REVISIONS. INCLUDE THE ENGINEER'S DESIGN FEES |
| AS REQUIRED BY SEC. 109.3 CITY AMENDMENTS |
| |
| NEW COMMENT: |
| 4- PATIO FRAMING PLAN ON SHEET S-2 SPECIFIES NEW W12X22 |
| STEEL BEAMS. DETAILS ON SHEET S-3 WERE NOT REVISED TO |
| SHOW THE CONNECTIONS OF WOOD JOISTS TO THE STEEL BEAM. |
| PROVIDE DETAILS FOR: |
| A) CONNECTION OF WOOD JOIST TO STEEL BEAM. SEC. R301.1 |
| FBC 2010. |
| |
| B) CONNECTION OF 3/4" PLYWOOD TO THE STEED BEAM. SEC. |
| R301.1 FBC 2010. |
| |
| C) CONNECTION OF 1X6 T&G WOOD CEILING TO STEEL BEAM. |
| SEC. R301.1 FBC 2010. |
| |
| 5- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| WOOD RAILING BY THE SPECIALTY ENGINEER AS SPECIFIED ON |
| DETAILS ON SHEET S-3. |
| SEC. R301.1 FBC 2010. NOTE: THIS INFORMATION NEED TO BE |
| PROVIDED FOR REVIEW PRIOR TO INSPECTIONS TO AVOID |
| CONFLICTS OR DELAYS. |
| |