Date |
Text |
2016-06-24 17:11:39 | 1ST REVIEW |
| |
| |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER LL |
| CITY OF WEST PALM BEACH |
| DEVELOPMENT SERVICES |
| BUILDING DIVISION |
| 561-805-6711 |
| [email protected] |
| |
| |
| PLUMBING COMMENTS: |
| |
| |
| 1. WATER FOUNTAIN REQUIRED FOR CHANGE OF OCCUPANCY |
| SHALL COMPLY WITH FBC PL [B] 410.2 MINIMUM NUMBER. |
| WHERE DRINKING FOUNTAINS ARE REQUIRED, NOT FEWER THAN |
| TWO DRINKING FOUNTAINS SHALL BE PROVIDED. ONE DRINKING |
| FOUNTAIN SHALL COMPLY WITH THE REQUIREMENTS FOR PEOPLE |
| WHO USE A WHEELCHAIR AND ONE DRINKING FOUNTAIN SHALL |
| COMPLY WITH THE REQUIREMENTS FOR STANDING PERSONS. |
| FBC PL TABLE 403.1/ A DRINKING FOUNTAIN COMPILING WITH |
| FBC ACC 211.2 MINIMUM NUMBER. |
| NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. |
| ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH |
| 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH |
| 602.7. |
| |
| 2. A SERVICE SINK IS REQUIRED FOR CHANGE OF OCCUPANCY |
| SHALL COMPLY WITH FBC PL TABLE 403.1 |
| |
| 3. PLEASE PROVIDE WATER RISER DIAGRAM .PER WPB AMEND TO |
| FBC 107.2.1 |
| |
| 4. PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE WATER |
| CLOSET SHALL COMPLY WITHE FBC ACC 604.3.1 SIZE. |
| CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES |
| (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE |
| WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED |
| PERPENDICULAR FROM THE REAR WALL. |
| |
| 4. PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE LAVATORY'S |
| SHALL COMPLY WITHE FBC ACC 606.2 CLEAR FLOOR SPACE. |
| A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR |
| A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE |
| COMPLYING WITH 306 SHALL BE PROVIDED. |
| |
| 5. PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE WATER |
| FOUNTAIN SHALL COMPLY WITHE FBC ACC 602.2 CLEAR FLOOR |
| SPACE. |
| UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE |
| COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH |
| AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE |
| COMPLYING WITH 306 SHALL BE PROVIDED. |
| |
| 6. THE DOOR TO BATHROOM SHALL COMPLY WITH FBC ACC |
| 603.2.3 DOOR SWING. |
| DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR |
| CLEARANCE REQUIRED FOR ANY FIXTURE. DOORS SHALL BE |
| PERMITTED TO SWING INTO THE REQUIRED TURNING SPACE. |
| |
| EXCEPTIONS: |
| |
| 1. DOORS TO A TOILET ROOM OR BATHING ROOM FOR A SINGLE |
| OCCUPANT ACCESSED ONLY THROUGH A PRIVATE OFFICE AND NOT |
| FOR COMMON USE OR PUBLIC USE SHALL BE PERMITTED TO |
| SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE PROVIDED |
| THE SWING OF THE DOOR CAN BE REVERSED TO COMPLY WITH |
| 603.2.3. |
| |
| 2. WHERE THE TOILET ROOM OR BATHING ROOM IS FOR |
| INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING WITH |
| 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE |
| DOOR SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE |
| CLEAR FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY |
| FIXTURE. |
| |
| 7. TOILET SHALL COMPLY WITH FBC ACC 604.2 LOCATION. |
| THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR |
| PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE |
| OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM |
| TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR |
| PARTITION, |
| 604.4 SEATS. |
| THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH |
| FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES |
| (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS |
| SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. |
| |
| 8. GRAB BARS SHALL COMPLY WITH FBC ACC 609.4 POSITION |
| OF GRAB BARS. |
| GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| THE GRIPPING SURFACE, |
| |
| |
| |
| |
| |
| |
| |
| DISREGARD COMMENTS BELOW |
2016-06-24 09:59:59 | NEED TO CORRECT DRAWING OF VENTING FOR FIXTURES NEED TO |
| HAVE BETWEEN W/C AND LAV. NEED TO HAVE SIZE OF VENTS ON |
| DRAWING |