Plan Review Notes
Plan Review Notes For Permit 16061174
Permit Number 16061174
Review Stop B
Sequence Number 4
Notes
Date Text
2017-02-01 09:20:10 
 BUILDING REVIEW APPROVED WITH PROVISO:
 1- PROVIDE COMPLETE DETAILS/SPECIFICATIONS FOR THE
 INSTALLATION OF BRICK VENEER, INCLUDING VENEER SUPPORTS
 AT OPENINGS. ALSO, SPECIFY WEEP-HOLES, ETC.
 NOTE: PROVIDE COMPLETE DETAILS/ SPECIFICATIONS. DON'T
 CITE CODE SECTIONS.
  
 2- ENERGY CALCULATIONS WERE REVISED FOR FULL HOUSE
 COMPLIANCE INSTEAD OF ADDITION ALONE:
 A) REVISE CEILING INSULATION ITEM #10 TO MATCH PLANS.
 VENTED AND UNVENTED ROOFS.
 B) REVISE ROOF MATERIAL SHOWN ON PAGE 2 OF 5 TO MATCH
 PLANS AND PRODUCT APPROVALS SUBMITTED.
 C) REVISE CONCRETE BLOCK INSULATION ITEM #9 DOESN'T
 MATCH PLANS. SEE DETAIL #2 ON SHEET A-10.
 D) REVISE R-VALUE SHOWN ON THE CEILING INSULATION ON
 PAGE 3 OF 5 TO MATCH PLANS AND INFORMATION SHOWN ON
 ITEM #10.
 E) REVISE DOOR TYPE SPECIFIED ON PAGE 3 OF 5 TO MATCH
 PLANS AND PRODUCT APPROVALS SUBMITTED. THERE ARE NO
 INSULATED DOORS. DOORS WITH GLASS NEED TO BE INCLUDED
 IN THE WINDOWS AREA.
 F) REVISE WINDOWS OVERHANG DEPTH AND SEPARATION TO
 MATCH PLANS.
 G) REVISE NUMBER OF OCCUPANTS ON PAGE 2 OF 5. WHY 20
 PEOPLE IN A SINGLE FAMILY RESIDENCE.
 H) REVISE FLOOR TYPES ON PAGE 2 OF 5. 2ND FLOOR IS NOT
 ON SLAB ON GRADE.
  
 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) GARAGE DOORS THAT MEETS ALL THE DESIGN LOADS SHOWN
 ON SHEET S-6 (POSITIVE AND NEGATIVE).
 B) DOUBLE EXTERIOR DOORS THAT MEET THE DESIGN PRESSURES
 SPECIFIED ON SHEET S-6 FOR FAMILY ROOM AREA.
  
 4- ENGINEER OF RECORD TO REVIEW AND APPROVE ABOVE
 PRODUCT APPROVALS.