Plan Review Notes
Plan Review Notes For Permit 16061174
Permit Number 16061174
Review Stop R
Sequence Number 1
Notes
Date Text
2016-08-08 14:41:561- SPECIFY THE ROOF PITCH FOR EXISTING PORCH LOCATED
 BETWEEN THE GARAGE AND MAIN HOUSE TO VERIFY COMPLIANCE
 WITH THE PROPOSED SHINGLES. ROOF PITCH SEEMS TO BE TOO
 LOW. AND SHINGLES MAY NO BE INSTALLED. LOW SLOPE ROOFS
 REQUIRE A DIFFERENT PRODUCT APPROVAL. SEC. R905.1
 FBC-RESIDENTIAL.
  
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) SHINGLES THAT MEET THE REVISED DESIGN PRESSURES
 CALCULATED ON SHEET. S-6. NOTE: THE DESIGN PRESSURES
 SHOWN ON NOA 12-0514.12 SUBMITTED MAY NOT RESIST THE
 REVISED DESIGN PRESSURES. VERIFY AND RE-SUBMIT.
  
 B) LOW SLOPE ROOF IF REQUIRED BY ITEM #14 ABOVE.
 IDENTIFY SELECTED ASSEMBLY. AND, PROVIDE SIGNED AND
 SEALED RAS 117 CALCULATIONS IF SELECTED ASSEMBLY
 DOESN'T MEET THE CALCULATED DESIGN PRESSURES.
  