Date |
Text |
2016-06-30 08:38:25 | PLAN REVIEW COMMENTS FOR SOLAR DOMESTIC WATER HEATER |
| |
| 1ST REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) THE FLORIDA LICENSED ENGINEER IS REQUIRED TO SIGN BY |
| HAND HIS HANDWRITTEN SIGNATURE (FACSIMILES ARE NOT |
| ACCEPTABLE) ON THE PLANS AND OTHER CONSTRUCTION |
| DOCUMENTS. FAC 61G15-23.002 DIGITAL SIGNATURES ARE ONLY |
| ACCEPTABLE ON ELECTRONICALLY SUBMITTED DOCUMENTS. |
| FAC61G15-23.003 |
| |
| 2) PLANS ARE REQUIRED TO BE DRAWN TO A MINIMUM 1/8 INCH |
| SCALE PER 107.2.1.4. |
| |
| 3) PROVIDE DOCUMENTATION FROM THE MANUFACTURED BUILDING |
| DESIGNER OF RECORD TO SHOW THAT THE BUILDING CAN SAFELY |
| SUPPORT ALL ADDITIONAL LOADING THAT MAY BE CREATED BY |
| INSTALLATION OF THIS PHOTOVOLTAIC SYSTEM AND SOLAR |
| WATER HEATER COLLECTOR ON THE ROOF. FBC-R 301.1 SUBMIT |
| A SIGNED AND SEALED LETTER FROM THE ENGINEER CERTIFYING |
| THAT HE HAS REVIEWED THE STRUCTURE AND FOUND IT TO BE |
| STRUCTURALLY CAPABLE OF SAFELY SUPPORTING ALL |
| ADDITIONAL LOADING THAT WILL BE CREATED BY INSTALLATION |
| OF THIS PHOTOVOLTAIC SYSTEM AND SOLAR WATER HEATER |
| COLLECTOR ON THE ROOF. FBCR M2301.2.2 |
| |
| 4) PROVIDE THE WIND DESIGN DATA ON THE PLANS. FBCR |
| 301.2.1 |
| |
| 5) PROVIDE THE MANUFACTURER'S SPECIFICATIONS, LISTING |
| AND INSTALLATION DETAILS FOR THE SOLAR WATER HEATER |
| SYSTEM. FBC 107.2.1 AND FBCR-M2301.3 |
| |
| 6) PROVIDE SPECIFIC MOUNTING AND ANCHORING DETAILS FOR |
| THE ROOF TOP SOLAR COLLECTOR. FBCR-M2301.2.2 AND |
| FBCR301.1 |
| |
| |
| |