2016-06-30 08:38:25PLAN REVIEW COMMENTS FOR SOLAR DOMESTIC WATER HEATER
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE FLORIDA LICENSED ENGINEER IS REQUIRED TO SIGN BY
 HAND HIS HANDWRITTEN SIGNATURE (FACSIMILES ARE NOT
 ACCEPTABLE) ON THE PLANS AND OTHER CONSTRUCTION
 DOCUMENTS. FAC 61G15-23.002 DIGITAL SIGNATURES ARE ONLY
 ACCEPTABLE ON ELECTRONICALLY SUBMITTED DOCUMENTS.
 FAC61G15-23.003
  
 2) PLANS ARE REQUIRED TO BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE PER 107.2.1.4.
  
 3) PROVIDE DOCUMENTATION FROM THE MANUFACTURED BUILDING
 DESIGNER OF RECORD TO SHOW THAT THE BUILDING CAN SAFELY
 SUPPORT ALL ADDITIONAL LOADING THAT MAY BE CREATED BY
 INSTALLATION OF THIS PHOTOVOLTAIC SYSTEM AND SOLAR
 WATER HEATER COLLECTOR ON THE ROOF. FBC-R 301.1 SUBMIT
 A SIGNED AND SEALED LETTER FROM THE ENGINEER CERTIFYING
 THAT HE HAS REVIEWED THE STRUCTURE AND FOUND IT TO BE
 STRUCTURALLY CAPABLE OF SAFELY SUPPORTING ALL
 ADDITIONAL LOADING THAT WILL BE CREATED BY INSTALLATION
 OF THIS PHOTOVOLTAIC SYSTEM AND SOLAR WATER HEATER
 COLLECTOR ON THE ROOF. FBCR M2301.2.2
  
 4) PROVIDE THE WIND DESIGN DATA ON THE PLANS. FBCR
 301.2.1
  
 5) PROVIDE THE MANUFACTURER'S SPECIFICATIONS, LISTING
 AND INSTALLATION DETAILS FOR THE SOLAR WATER HEATER
 SYSTEM. FBC 107.2.1 AND FBCR-M2301.3
  
 6) PROVIDE SPECIFIC MOUNTING AND ANCHORING DETAILS FOR
 THE ROOF TOP SOLAR COLLECTOR. FBCR-M2301.2.2 AND
 FBCR301.1
  
  
  