Plan Review Notes For Permit 16060248 |
Permit Number |
16060248 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2016-07-15 09:24:03 | APPROVED WITH EXCEPTIONS | | 1) FBC ACCESSIBILITY SECTION 505.4 REQUIRES THE TOP OF | | THE RAMP AND LANDING HANDRAILS TO BE A MAXIMUM OF 36 | | INCHES MEASURED VERTICALLY ABOVE WALKING SURFACES AND | | RAMPS. FBC 1013.2 REQUIRES GUARDS WHEN THE RAMPS AND | | LANDINGS ARE MORE THAN 30 INCHES MEASURED VERTICALLY | | FROM GRADE AT ANY POINT WITHIN 36" HORIZONTALLY TO THE | | OPEN SIDE. THIS RAMP AND LANDING IS 21" ABOVE GRADE PER | | THE PLANS, SO ONLY THE HANDRAILS ARE REQUIRED. | | | | 2) FBC ACCESSIBILITY SECTION 307.4 REQUIRES THE | | HANDRAIL EXTENSION RETURN TO BE 27 INCHES MAXIMUM ABOVE | | THE LOWER LANDING. | | |
|