Plan Review Notes
Plan Review Notes For Permit 16060023
Permit Number 16060023
Review Stop G
Sequence Number 1
Notes
Date Text
2016-06-06 05:49:121) SUBMIT TWO COPIES OF A PLAN SHOWING THE LOCATION OF
 THE EXISTING WATER HEATER AND THE NEW TANKLESS WATER
 HEATER. INDICATE ON THE PLANS IF IT IS BEING INSTALLED
 IN THE SAME LOCATION AS THE EXISTING.
 2) INDICATE THE BTU LOAD OF THE TANKLESS UNIT ON THE
 REQUIRED PLANS AND ALSO ON THE SPECIFICATIONS.
 3) SUBMIT A GAS DRAWING SHOWING ALL OTHER EXISITNG GAS
 APPLIANCES IN THE STRUCTURE.SHOW ALL EXISTING PIPE
 SIZES, TYPE OF PIPE MATERIAL, PSI OF THE SYSTEM, TOTAL
 DEVELOPED LENGTH FROM THE METER TO THE MOST REMOTE
 OUTLET AND TOTAL BTU LOAD ON THE SYSTEM,
 4) MANUF. INSTALLATION MANUAL SHALL BE ONSITE FOR
 INSPECTION.
 5) A SEPARATE ELECTRIC PERMIT IS REQUIRED FOR THE
 ELECTRONIC IGNITION.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  