Plan Review Notes
Plan Review Notes For Permit 16051235
Permit Number 16051235
Review Stop B
Sequence Number 1
Notes
Date Text
2016-06-23 08:15:39BUILDING PLAN REVIEW
 W. P. B. PERMIT:16051235
 ADD: 880 VALLEY FORGE RD.
 CONT: FLORIDA DESIGN DRILLING CORP.
 TEL: 561-844-2966
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: THURS. JUNE 23/2016
 ACTION: DENIED
  
  
 1) PLEASE NOTE SHEET S-2 INDICATES UNDER NOTE # 1 THIS
 IS A PRE-MANUFACTURERED BUILDING. PRE-MANUFACTURED
 BUILDINGS ARE BUILT AT A PLANT TOTALLY COMPLETE. FOR
 MANUFACTURERED BUILDINGS (MODULAR)AT A PLANT AND
 TRANSPORTED COMPLETE TO THE JOBSITE, THEY HAVE TO BE
 PART OF THE STATE MANUFACTURED BUILDING PROGRAM IN
 COMPLIANCE WITH :
 FLORIDA STATUTE 428.3 INSPECTIONS. INSPECTION OF
 INSTALLATION OF MANUFACTURED BUILDINGS AND CONSTRUCTION
 ACTIVITIES CONDUCTED AT THE SITE OF THE INSTALLATION
 SHALL BY CONDUCTED PURSUANT TO CHAPTER 1 HEREOF.
 INSPECTIONS DURING THE MANUFACTURING PROCESS SHALL BE
 CONDUCTED BY THOSE THIRD-PARTY AGENCIES
  
 THIS BUILDING IS SITE BUILT W/ OFF SITE
 PRE-MANUFACTURED PANELS. PLEASE CORRECT THE
 TERMINOLOGY. THE ISSUE WE HAVE WITH THIS BUILDING IS ON
 SHEET S-1 NOTES INDICATE FABRICATION AND ERECTION
 DRAWINGS WILL BE PREPARED BY A DELEGATE ENGINEER.
  
 WHAT WE ARE NOT GETTING IS THE INSPECTION OF THE STEEL
 (REBAR) AND EMBEDS IN THE STRUCTURAL WALL AND ROOF
 PANEL OR PANELS. THIS NEEDS TO BE COMPLETED BY A STATE
 CERTIFIED BUILDING INSPECTOR WHO HOLDS A BN LICENSE.
 THIS IS NOT A MODULAR BUILDING UNDER THE STATE PROGRAM.
 FLORIDA STATUTE 428.3 INSPECTIONS. INSPECTION OF
 INSTALLATION OF MANUFACTURED BUILDINGS AND CONSTRUCTION
 ACTIVITIES CONDUCTED AT THE SITE OF THE INSTALLATION
 SHALL BY CONDUCTED PURSUANT TO CHAPTER 1 HEREOF.
 INSPECTIONS DURING THE MANUFACTURING PROCESS SHALL BE
 CONDUCTED BY THOSE THIRD-PARTY AGENCIES FLORIDA ADMIN.
 CODE CHAPTER 61-41 MANUFACTURERED BUILDINGS.
  
 FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL
 FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE
 ENGINEER OF RECORD FOR REVIEW BEFORE BEING SUBMITTED TO
 THE BUILDING DEPARTMENT.
  
 2) ALL ONSITE WELDING OF EMBEDS TO PANEL SYSTEMS EITHER
 WALL OR ROOF PANELS WILL NEED TO BE COMPLETED BY A
 CERTIFIED WELDER, PLEASE PROVIDE PAPERWORK INDICATING
 THEIR CERTIFICATION.
  
 3) PLEASE PROVIDE COMPLIANCE WITH: 2014 FBC-B
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (C) PANEL WALLS: WALL LOUVERS
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 4) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.3.4 DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE. THE REGISTERED DESIGN
 PROFESSIONAL IN RESPONSIBLE CHARGE SHALL BE RESPONSIBLE
 FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS
 PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED
 SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF
 THE BUILDING. THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 5) SHEET S2 THE WALL INTERIOR ZONE # 4 PRESSURES ARE IN
 VULT PLEASE PROVIDE THE PRESSURES IN VASD SINCE THE
 PRODUCT APPROVALS ARE ALL IN VASD. 2014 FBC-B 1609.3.1
 WIND SPEED CONVERSION VULT TO VASD.
  
 6) SHEET S2 SHOWS COMPONENT AND CLADDING PRESSURES FOR
 THE WALL ZONES BUT THERE ARE NO PRESSURES FOR THE FLAT
 CONCRETE ROOF ZONES 1, 2 NOR 3. 2014 FBC-B 1603.1.4
 WIND DESIGN DATA. PLEASE CONVERT PRESSURES TO VASD.
 2014 FBC-B 1609.3.1 WIND SPEED CONVERSION VULT TO VASD.
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved