2016-07-05 13:47:24 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW |
| COMMENTS. |
| CODE: FBC 5TH EDITION (2014) |
| |
| 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER, |
| THE FIRST FLOOR IS UNFINISHED STORAGE. THERE ARE NO |
| CITY RECORDS FOR THE CONSTRUCTION OF AN APARTMENT AS |
| SHOWN ON PLANS SUBMITTED. IN ADDITION ZONING DOESN'T |
| ALLOW ANOTHER APARTMENT. ZONING MAY ALLOW ADDITIONAL |
| LIVABLE AREA BUT NO AN INDEPENDENT APARTMENT. AFTER THE |
| PLANS ARE REVISED, BRING PLANS TO PALM BEACH COUNTY |
| (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. BRING |
| BACK COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF |
| FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE |
| UNIFIED LAND DEVELOPMENT CODE. |
| |
| 2- FIRST FLOOR PLAN LAYOUT AND SECOND FLOOR PLAN LAYOUT |
| ARE EXACTLY THE SAME BUT THE NAMES OF THE ROOMS ARE |
| DIFFERENT. THE PROPOSED USE AND OCCUPANCY OF THE FIRST |
| FLOOR IS NOT CLEAR. FOR EXAMPLE, THE LAYOUT SHOWS A |
| ROOM WITH A CLOSET AND A BATHROOM, BUT IT IS CALLED |
| "ENTERTAINMENT ROOM". THIS IS GENERALLY USED AS A |
| BEDROOM AS SHOWN ON THE SECOND FLOOR PLAN. (PLAN REVIEW |
| WILL BE DONE BASED ON THE BEDROOM USE). THE LAYOUT ALSO |
| SHOWS A KITCHEN AND A LIVING ROOM, BUT IT IS CALLED |
| "EXERCISE, RECREATIONAL & ENTERTAINMENT ROOM". THIS IS |
| GENERALLY USED AS KITCHEN AND LIVING ROOM AS SHOWN ON |
| THE SECOND FLOOR PLAN. ALSO, THE ELECTRICAL FLOOR PLANS |
| SHOW TWO SEPARATE METERS. CLARIFY, WHY PROVIDING TWO |
| SEPARATE METERS IF ONLY ONE UNIT IS ALLOWED. NOTE: |
| ELECTRICAL MAY MAY NEED TO BE REVISED. |
| FOR YOUR INFORMATION ZONING MAY ALLOW THE CONVERSION OF |
| THE FIRST FLOOR FROM STORAGE TO LIVABLE SPACE WITH SOME |
| RESTRICTIONS. COORDINATE WITH ZONING FOR ALLOWED USE. |
| CLEARLY DEFINE THE USE AND OCCUPANCY OF EACH ROOM TO |
| PERFORM A PROPER PLAN REVIEW. REVISE PLANS AS REQUIRED |
| TO VERIFY COMPLIANCE WITH THE PROPOSED USE AND |
| OCCUPANCY. SEC. 102.2 CITY AMENDMENTS. |
| |
| 3- COORDINATE WITH ITEM #3 ABOVE AND PROVIDE COMPLIANCE |
| WITH THE EGRESS REQUIREMENTS OF THE BEDROOM ON THE |
| FIRST FLOOR PLAN. SPECIFY WINDOW TYPE, SIZE. SEC. R310 |
| FBC-RESIDENTIAL, 5TH EDITION (2014). |
| |
| 4- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT |
| OF WORK TO BE PERFORMED. SPECIFY WHAT'S NEW , WHAT'S |
| EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS. |
| |
| 5- SECOND FLOOR PLAN IS NOT DRAWN CORRECTLY. IT IS |
| CONFUSING. IT SHOWS THE APARTMENT ENTRY DOOR THAT IS |
| LOCATED ON THE FIRST FLOOR PLAN. REVISE AS REQUIRED. |
| SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 6- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE |
| PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. |
| 107.2.1 CITY AMENDMENTS. |
| |
| 7- THIS HOUSE IS A CONTRIBUTING HISTORIC HOUSE. IT IS |
| EXEMPT FROM THE ENERGY CODE. ENERGY CALCULATIONS ARE |
| NOT REQUIRED, BUT IF CONTRACTOR WANTS TO SUBMIT THEM, |
| THEN REVISE THE FOLLOWING: |
| A) CLARIFY WHY SUBMITTING ONE ENERGY CALCULATIONS PER |
| FLOOR. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| B) OWNER INFORMATION IS INCORRECT. SEC. R101.5.1.1.2 |
| FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| C) THE PERMIT OFFICE IS INCORRECT. THE PERMIT OFFICE IS |
| CITY OF WEST PALM BEACH NOT PALM BEACH. TWO DIFFERENT |
| MUNICIPALITIES. SEC. R101.5.1.1.2 FBC-ENERGY |
| CONSERVATION, 5TH EDITION (2014). |
| |
| D) SPECIFY THE JURISDICTION NUMBER. SEC. R101.5.1.1.2 |
| FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| E) THIS IS NOT AN ADDITION. SEE PLANS. SEC. |
| R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| (2014). |
| |
| F) NUMBER OF BEDROOMS IS INCORRECT. SEC. R101.5.1.1.2 |
| FBC-ENERGY CONSERVATION, 5TH EDITION (2014). NOTE: THIS |
| APPLIES TO THE ENERGY CALCULATIONS OF THE 1ST FLOOR. |
| COORDINATE WITH REVISED PLANS AS REQUIRED BY ITEM #2 |
| ABOVE. |
| |
| G) CONDITIONED FLOOR AREA IS INCORRECT. IT DOESN'T |
| MATCH PLANS. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, |
| 5TH EDITION (2014). |
| |
| H) PROVIDE MANUFACTURER'S DOCUMENTATION SHOWING THE |
| DOORS AND WINDOWS U-FACTOR AND SHGC FACTOR SPECIFIED ON |
| ITEM #7. SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH |
| EDITION (2014). |
| |
| I ) THE FLOOR TYPE AND INSULATION R-VALUE (ITEM #8) FOR |
| THE SECOND FLOOR ENERGY CALCULATIONS IS INCORRECT. |
| THERE IS NOT SLAB ON GRADE FOR THE SECOND FLOOR. SEC. |
| R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| (2014). |
| |
| J) PROVIDE MANUFACTURER'S INFORMATION SHOWING HOW |
| PROVIDING R-19 INSULATION ON THE WALLS. CHECK THICKNESS |
| OF WALL AND THICKNESS OF PROPOSED INSULATION. SEC. |
| R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| K) CLARIFY HOW THE CEILING OF THE FIRST FLOOR ENERGY |
| CALCULATIONS IS VENTED AS SPECIFIED ON ITEM #10. SEC. |
| R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| L) PROVIDE THE NAME OF THE PERSON PREPARING THE ENERGY |
| CALCULATIONS AS REQUIRED BY SEC. R405.4.2 FBC-ENERGY |
| CONSERVATION, 5TH EDITION (2014). |
| |
| M) OWNER/AGENT TO CERTIFY AND DATE THE ENERGY |
| CALCULATIONS AT THE BOTTOM OF THE FORM AS REQUIRED BY |
| SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION |
| (2014). |
| |
| N) PAGE 2 OF 4 OF THE ENERGY CALCULATIONS FOR THE FIRST |
| FLOOR SPECIFY THAT THERE IS A KITCHEN. FIRST FLOOR IS |
| NOT ALLOWED TO HAVE A KITCHEN. SEE ZONING COMMENTS. |
| COORDINATE WITH REVISED PLANS AND REVISE CALCULATIONS |
| AS REQUIRED. SEC. R103.2 FBC-ENERGY CONSERVATION, 5TH |
| EDITION (2014). |
| |
| O) ROOFING MATERIAL SHOWN ON PAGE 2 OF 4 IS INCORRECT. |
| ACCORDING TO CITY RECORDS THE LAST ROOFING PERMIT |
| APPLICATION FOR THE REAR STRUCTURE WAS FOR SHINGLES NOT |
| BARREL TILE. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, |
| 5TH EDITION (2014). |
| |
| P) WINDOWS OVERHANG SEPARATION SHOWN ON PAGE 2 OF 4 IS |
| INCORRECT. IT DOESN'T MATCH PLANS. SEC. R101.5.1.1.2 |
| FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE |
| NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD |
| DRAWINGS FOR REFERENCE. |
| |