2016-08-29 13:37:59 | MAIN HOUSE: |
| RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING |
| REVIEW CHECKLIST. |
| CODE: FBC 5TH EDITION (2014) |
| |
| ORIGINAL COMMENT: |
| 1- PROVIDE COMPLIANCE WITH THE EGRESS REQUIREMENTS OF |
| BEDROOM #1 SHOWN ON THE FIRST FLOOR PLAN. SPECIFY |
| WINDOW TYPE, SIZE AND SILL HEIGHT SEC. R310 |
| FBC-RESIDENTIAL, 5TH EDITION (2014). |
| |
| RESPONSE: |
| THE EMERGENCY ESCAPE SHALL OPEN DIRECTLY INTO A PUBLIC |
| WAY OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. |
| SEE SEC. R310.1 FBC-RESIDENTIAL. THE DOORS SHOWN ON |
| FLOOR PLAN DON'T COMPLY. THEY DON'T OPEN INTO A PUBLIC |
| WAY OR YARD OR COURT THAT OPENS TO A PUBLIC WAY. REVISE |
| PLANS AS REQUIRED. |
| |
| ORIGINAL COMMENT: |
| 2- SCOPE OF WORK IS NOT CLEAR. CLEARLY SPECIFY EXTENT |
| OF WORK TO BE PERFORMED. WHY SUBMITTING PRODUCT |
| APPROVAL FOR SINGLE HUNG WINDOWS. WHAT'S NEW , WHAT'S |
| EXISTING, ETC. SEC. 107.2.1 CITY CITY AMENDMENTS. |
| |
| RESPONSE: |
| (1) SCOPE BUILDING NOTE #1 INDICATES "REPAIR DAMAGED |
| EXISTING FRAMING AND STUCCO ON EXISTING EXTERIOR WALL". |
| NEED TO INDICATE ON PLANS DAMAGED AREAS AND PROVIDE |
| COMPLETE DETAILS AND SPECIFICATIONS FOR THE PROPOSED |
| REPAIR. SPECIFY ALL FRAMING MEMBERS AND CONNECTORS. |
| SEC. R301.1 FBC-RESIDENTIAL, 5TH EDITION (2014). |
| |
| (2) SCOPE BUILDING NOTE #3 INDICATES "INSTALL NEW |
| INTERIOR FRAMING TO CREATE NEW UPSTAIRS BATHROOM |
| ATTACHED TO MASTER BEDROOM". PROVIDE COMPLETE FRAMING |
| PLANS AND SPECIFICATIONS. SPECIFY ALL FRAMING MEMBERS |
| AND CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL, 5TH |
| EDITION (2014). |
| |
| ORIGINAL COMMENTS: |
| 3- SPECIFY CARBON MONOXIDE ALARMS FOR ALL BEDROOMS |
| SHOWING COMPLIANCE WITH SEC. R315 FBC-RESIDENTIAL. |
| |
| RESPONSE: |
| CARBON MONOXIDE ALARMS TO BE INCLUDED IN THE ORIGINAL |
| DRAWING. CORRECTIONS BY HAND ON SUBMITTED COPIES ARE |
| NOT ALLOWED. |
| |
| ORIGINAL COMMENT: |
| 4- PROVIDE THE NAME AND SIGNATURE IN ALL PLANS OF THE |
| PERSON RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. |
| 107.2.1 CITY AMENDMENTS |
| |
| RESPONSE: |
| STILL MISSING THE NAME OF THE PERSON RESPONSIBLE FOR |
| THE DESIGN. |
| |
| **** PLEASE REMOVE ANY REVISED DRAWING AND INSERT THE |
| NEW DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMITT OLD |
| DRAWINGS FOR REFERENCE. |
| |