2016-06-09 13:56:34 | 501 SOUTH FLAGLER DRIVE #600 | | PERMIT #16051101 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SHEET ALS.1.1: THE BUSINESS LOUNGE ASSEMBLY ROOM HAS AN | | OCCUPANCY LOAD OF 53 AND IS PROVIDED WITH 3 EXIT ACCESS | | DOORS SWINGING IN THE DIRECTION OF TRAVEL; HOWEVER, TWO | | OF THESE DOORS (#622 AND #624) ARE ALSO EXIT ACCESS | | DOORS FOR THE REST OF THE FLOOR AND ALSO REQUIRED TO | | SWING IN THE DIRECTION OF TRAVEL (OPPOSITE CURRENT | | SWING) BECAUSE THEY HAVE THE POTENTIAL TO SERVE MORE | | THAN 50 PERSONS. THESE DOORS WILL ALSO REQUIRE PANIC | | HARDWARE IF THEY ARE EUIPPED WITH A LATCH. | | | | WESLEY JOLIN | | ASSISTANT FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|