2016-06-14 13:35:15BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16051101
 ADD: 501 S. FLAGLER DR. 6TH FLOOR
 CONT: ANDERSON MOORE
 TEL: 561-662-1819
 E-MAIL: RKENNEY@AMC_BUILD.COM
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JUNE 14/ 2016
 ACTION: DENIED
  
 1) SHEET 002 ALS-1-1. UNDER THE HEADING OF CODE DATA:
 1A) THE PLANS INDICATE UNDER THE HEADING USE GROUP: A
 BUSINESS AND ASSEMBLY OCCUPANCY. THE CODE DATA SHEET
 DOES NOT DECLARE IF THIS TENANCY IS TO BE A MIXED USE
 OCCUPANCY SEPARATED (FBC-B508.2.4) OR NON-SEPARATED
 OCCUPANCIES (FBC-B 50508.3). THE ASSEMBLY USAGE IS OVER
 10 % OF THE FLOOR PLATE CREATING MIXED USE OCCUPANCY.
  
 1B) WITH THE MIXED USE OCCUPANCY THE CONSTRUCTION TYPE
 FOR THE BUILDING HAS TO BE REVIEWED AS WELL. THE CODE
 DATA SHEET LIST THE BUILDING TYPE AS A IIA. FOR THE
 ASSEMBLY OCCUPANCY A BUILDING CONSTRUCTION TYPE IIA IS
 GOOD FOR 3 FLOORS + 1 FLOOR FOR A FULL NFPA 13
 SPRINKLER SYSTEM. THIS BUILDING TYPE FOR A MINIMUM
 WOULD BE REQUIRED TO BE A IB NOT A IIB, SEE 2014 FBC-B
 TABLE 503.
  
 2) SHEET ALS.1.1. PLEASE REVIEW THE DOOR SWING FOR DOOR
 NUMBERS 622 & 623. THE OCCUPANT LOAD SERVED BY THESE
 DOORS IS 50 OR MORE REQUIRING THEM TO SWING IN THE
 DIRECTION OF TRAVEL. 2014 FBC-B 1008.1.2.
  
 3) LETTER FROM GLIDDENSPINA IS FOR SHOWING COMPLIANCE
 TO THE 2014 ACCESSIBILITY CODE IN REGARDS TO 202.4.1
 DISPROPORTIONATE COST AND 202.4.2 ACCESSIBLE FEATURES
 IN THE EVENT OF DISPROPORTIONALITY. THE LETTER LIST
 SIGNAGE, HARDWARE, CARPET, VCT & TILE OR 20% OF THE
 CONTRACT VALUE. THE LETTER DOES NOT SHOW WHAT
 ACCESSIBLE FEATURES WERE MADE TO BE ACCESSIBLE. THE
 DEMOLITION PAGE SHOWS THE WHOLE FLOOR BEING DEMOLISHED
 WITH THE EXCEPTION OF THE COMMON AREA RESTROOMS WHICH
 ARE OUT OF THE TENANT AREA BUILD OUT. PLEASE PROVIDE A
 LETTER GIVING THE DESCRIPTION OF THE ELEMENT BEING
 CORRECTED AND THE DOLLAR AMOUNT FOR EACH ACCESSIBLE
 ELEMENT CORRECTED. THE$41,060.00 IN ACCESSIBLE UPGRADES
 ARE TO BE SPENT IN THIS ORDER :
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
 WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH
 OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST
 ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE
 DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  