2016-05-24 17:27:06RESIDENTIAL (R3) FRONT BUILDING, RE-ROOF BUILDING
 REVIEW COMMENTS
 CODE: FBC 5TH EDITION (2014).
  
 1- FLAT ROOF ASSEMBLY W-51 FROM FLORIDA PRODUCT
 APPROVAL FL2533-R15 DOESN'T MEET THE DESIGN PRESSURES
 FOR ROOF ZONE #3. THE DESIGN PRESSURES FOR SELECTED
 ASSEMBLY ARE -105.0 PSF. THIS PROPERTY SEEMS TO BE
 LOCATED IN EXPOSURE "D" AND THE DESIGN PRESSURES FOR
 ZONE #3 ARE HIGHER THAN -105.0 PSF. SEC. R301.2.1.4.3
 FBC-RESIDENTIAL, 5TH EDITION (2014). NEED TO PROVIDE
 SIGNED AND SEALED RAS 117 CALCULATIONS TO MEET THE
 DESIGN PRESSURES FOR ZONE #3, SPECIFY ANOTHER ASSEMBLY
 THAT MEETS THE DESIGN PRESSURES FOR ZONE #3 OR PROVIDE
 ANOTHER PRODUCT APPROVAL WITH ASSEMBLY THAT MEETS THE
 DESIGN PRESSURES FOR ALL ROOF ZONES. NOTE: COORDINATE
 WITH ITEM #2 BELOW REGARDING FLORIDA PRODUCT APPROVAL
 SUBMITTED..
  
 2- PROVIDE CURRENT PRODUCT APPROVAL. FLORIDA PRODUCT
 APPROVAL FL2533-R15 SUBMITTED WAS REVISED WITH REVISION
 #16. PROVIDE 2 COPIES OF REVISED FL2533-R16.
 FAC 61G20-3.002(33).
  
 3- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR THE
 GALVANIZED ROOF VENTS SPECIFIED ON THE PROPOSAL
 SUBMITTED. FAC 61G20-3.002(33).
  