Date |
Text |
2016-05-18 09:34:12 | 1ST REVIEW: FBC 2014 |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| 561-805-6711 |
| [email protected] |
| |
| PLUMBING COMMENTS: |
| |
| 1. DRINKING FOUNTAIN SHALL COMPLY WITH FBC ACC SEC. |
| 602.4- 306 - 307 SHOW ON PLAN. |
| PER WPB AMEND. TO FBC 107.2.1 |
| |
| 2. MIRROR SHALL BE 40IN. MAX ABOVE FLOOR PER FBC ACC |
| SEC. 603.3 |
| |
| 3. SHOW WATER CLOSET 16IN MIN AND 18IN MAX FROM SIDE |
| WALL PER FBC ACC SEC. 604.2 |
| |
| 4. SHOW GRAB BARS TO COMPLY WITH FBC ACC SEC. |
| 604.5.2 REAR WALL. |
| THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG |
| MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER |
| CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 |
| INCHES (610 MM) MINIMUM ON THE OTHER SIDE. |
| 604.5.1 SIDE WALL. |
| THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) |
| LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM |
| THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM |
| FROM THE REAR WALL. |
| |
| 5. TOILET PAPER DISPENSER SHALL COMPLY WITH FBC ACC |
| SEC. 604.7 DISPENSERS. |
| TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL |
| NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES |
| NOT ALLOW CONTINUOUS PAPER FLOW. |
| |
| 5. KITCHEN SINKS SHALL COMPLY WITH FBC ACC SEC. 606.2 |
| CLEAR FLOOR SPACE. |
| A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR |
| A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE |
| COMPLYING WITH 306 SHALL BE PROVIDED. |
| 606.3 HEIGHT. |
| LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT |
| OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES |
| (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |