Plan Review Notes
Plan Review Notes For Permit 16050192
Permit Number 16050192
Review Stop B
Sequence Number 1
Notes
Date Text
2016-05-25 13:29:35BUILDING PLAN REVIEW
 W.P.B. PERMIT NO.: 16050192
 ADD: 7800 S. OLIVE AVE.
 CONTR: BELLA CONSTRUCTION
 TEL: 722-6402
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE
 W/ 2014 WEST PALM BEACH AMENDMENTS
 TO THE FLORIDA BUILDING CODE, CHPT. 1, ADMINISTRATION
  
 1ST REVIEW
 DATE: 5/25/16
 ACTION: FAILED
  
 1. CHANGE CODE REFERENCE ON PLANS FROM 2015 FBC TO 2014
 FBC 5TH ED.
 2, SEPERATE PERMIT REQUIRED FOR ACCESSORY STRUCTURE
 (GARAGE).
 3. SEPERATE PERMITS REQUIRED FOR ELECTRIC, MECH. &
 PLUMBING, (BOTH STRUCTURES).
 4. PERMIT FOR REPLASCEMENT OF WINDOWS AND DOORS ISSUED
 WITHIN THE LAST TWELVE MONTHS. PERMIT # 16020020, VALUE
 $15,437.00. CUMULATIVE VALUE FOR SCOPE OF WORK ON
 CURRENT APPLICATION IS $83,775.00.
 TOTAL VALUE OF WORK ($99,212.00) EXCEEDS 30% OF MARKET
 VALUE ($221,285). CLASSIFICATION OF WORK IS A
 RENOVATION.
 5. PROVIDE ENERGY CALCULATIONS PER FBCE 103.2.1.1
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
 (MANDATORY).
 THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY
 PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND
 CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT
 BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY.
 FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)]
 REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN
 ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND
 NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD
 CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE
 LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A
 DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT
 THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE
 BUILDER ACCURATELY REFLECTS THE PLANS AND
 SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE
 FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE
 FOUND IN APPENDIX C.
  
  
  
  
  
  
  
  