2016-05-23 12:15:51 | FAILED |
| |
| PLEASE PROVIDE RESPONSES TO THE COMMENTS IN WRITING |
| |
| 1) THE CITYPLACE MANAGEMENT APPROVAL STAMP IS REQUIRED |
| ON THE PLANS. |
| |
| 2) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS |
| SHALL PROVIDE A MINIMUM OF EIGHT (8) FEET OF CLEARANCE |
| BETWEEN THE FLOOR AND THE LOWEST POINT OF THE AWNING. |
| |
| A. THE PERMIT FOR THE EXTERIOR TENANT FACADE |
| RENOVATIONS SHOWS THE ENTRANCE AND WINDOW AWNINGS AT 8+ |
| FEET FROM THE SIDEWALK LEVEL; HOWEVER, THE AWNING |
| PERMIT DOES NOT SHOW THE LOCATION OF THE AWNING ON THE |
| BUILDING FACADE AND THE HEIGHT. PROVIDE A FACADE |
| ELEVATION WITH DIMENSIONS. |
| B. THE PERMIT FOR THE EXTERIOR TENANT FACADE |
| RENOVATIONS SHOWS THE DINING AREA AWNING AT 9 FEET FROM |
| THE SIDEWALK LEVEL; HOWEVER, THE AWNING PERMIT SHOWS A |
| 13 FOOT CLEARANCE. ALL PLANS SHALL SHOW THE SAME |
| CONDITION. |
| |
| 3) IT APPEARS THAT THE WEST DINING AREA "AWNING" IS |
| SUPPORTED BY POSTS ON THE AWING PERMIT AND THUS CANNOT |
| BE APPROVED UNLESS A MINOR PLANNED DEVELOPMENT |
| AMENDMENT IS APPROVED BY THE PLANNING DIVISION. THIS IS |
| DUE TO THE SUPPORT POSTS. THIS IS NOW A CANOPY |
| EXTENSION OF THE BUILDING AND NO LONGER AN AWNING. THE |
| TRUE AWNINGS THAT ARE ONLY ATTACHED TO THE BUILDING DO |
| NOT NEED THE AMENDMENT AND ONLY NEED APPROVAL AS PART |
| OF A BUILDING PERMIT. |
| |
| 4) THE MINOR AMENDMENT SHALL INCLUDE DETAILS OF THE |
| SUPPORT POSTS, PICTURES OF THE CANOPY AND A SURVEY/SITE |
| PLAN SHOWING THE OUTDOOR SEATING AREA AND ITS |
| DIMENSIONS, TO INCLUDE THE SETBACK TO THE CURB LINE. |
| PLEASE NOTE THAT THE RESTAURANT BUILD-OUT PLANS DO NOT |
| SHOW THE POSTS AND STAFF IS CONCERNED THAT THE POSTS |
| WILL INTERFERE WITH MOBILITY THROUGH THE OUTDOOR DINING |
| AREA. |
| |
| 5) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT AWNINGS |
| ON THE STREET LEVEL SHALL PROJECT FOUR (4) FEET FROM |
| THE BUILDING FACADE, UNLESS OTHERWISE APPROVED BY |
| CITYPLACE RETAIL IN WRITING. THIS APPLIES TO THE |
| ENTRANCE AWNING. YOU WOULD NEED TO PROVIDE A NOTARIZED |
| LETTER FROM CITYPLACE THAT THEY HAVE GRANTED THIS |
| SPECIFIC VARIANCE. |
| |
| 6) THE CITYPLACE MASTER SIGN PLAN REQUIRES THAT ALL |
| AWNINGS ON STREET LEVEL SHALL HAVE AN EIGHT (8) INCH |
| VERTICAL VALANCE ALONG THE FRONT OF THE AWNING. ALL OF |
| THE AWNINGS INCLUDED WITH THIS PERMIT HAVE A 14 INCH |
| VALANCE. ADDITIONALLY, THE VALANCE MUST BE PROVIDED |
| WITH CONCEALED WEIGHT TO PREVENT EXCESSIVE MOVEMENT IN |
| HIGH WINDS. |
| |
| A COPY OF THESE COMMENTS HAS BEEN SENT TO CARLOS BERNAL |
| AT CITYPLACE. |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
| |