Plan Review Notes For Permit 16041150 |
Permit Number |
16041150 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2016-05-20 06:33:25 | 1) THE PLANS SHOW THE POOL WATER WASTE DISCHARGE TO THE | | SANITARY SEWER.POOL WATER CANNOT DISCHARGE TO THE | | SANITARY OR STORM SYSTEM PER WPB CITY ORD. SECS. 90-126 | | (5), 90-203 (A), 90-204, AND 90-205 (1). THE RESPONSE | | FROM THE ENGINEER OF RECORD STATES THAT THIS ISSUE HAS | | BEEN RESOLVED AND THE WASTE WATER WILL GO TO THE | | SANITARY. I DO NOT HAVE ANY DOCUMENTATION THAT THIS | | WILL BE ALLOWED. | | 2) THE HYDRAULIC CALCULATIONS THAT WERE DONE ON SHT. 4 | | TO REDUCE THE CAPACITY OF THE COLLECTOR TANKS WERE | | BASED ON A FLOW RATE OF 185 GPM BUT THE FLOW RATE ON | | SHT.1 IN THE POOL DATA TABLE SHOWS A FLOW RATE OF 155 | | GPM. CLARIFY. | | 3) THERE WAS NO MSDS DOCUMENTATION ATTACHED TO THE | | RESPONSE LETTER FROM THE ENGINEER AS NOTED IN HIS | | RESPONSE TO COMMENT # 8. CLARIFY. | | 4) THERE WERE NO SPECIFICATIONS SUBMITTED FOR THE POOL | | HEATER. THIS INFORMATION CAN BE SUBMITTED WHEN THE GAS | | PERMIT IS SUBMITTED. | | | | PLUMBING PLAN REVIEW | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | 561-805-6692 | | [email protected] | | | | | | |
|