Plan Review Notes
Plan Review Notes For Permit 16041147
Permit Number 16041147
Review Stop B
Sequence Number 2
Notes
Date Text
2016-07-21 13:50:38BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16041147
 ADD: 914 3RD ST.
 CONT: TREND WEST INC.
 TEL: 561-358-8817
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. JULY 21 /16
 ACTION: DENIED
  
 1) SHEET S1:
  
 1A) 2ND REQUEST. THIS SHEET AND THE ELECTRICAL SHEETS
 SHOW 5 DWELLING UNITS, BUT THE DESIGNER OF RECORD MAKE
 NUMEROUS MENTION TO THE2014 RESIDENTIAL CODE. PLEASE
 NOTE THE FBC- RESIDENTIAL CODE IS FOR 1 & 2 FAMILY
 ONLY!!!!! PLEASE NOTE THIS 5 UNIT RESIDENTIAL STRUCTURE
 IS COVERED AND TO BE REVIEWED UNDER THE 2014
 FBC-BUILDING CODE- BUILDING CODE. PLEASE CORRECT THE
 CODE REFERENCES TO THE RESIDENTIAL CODE.
  
 1B) 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE
 EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL
 SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND
 DOCUMENTS: A FLOOR PLAN MISSING FROM THE 2ND REVIEW.
  
 107.3.5..11 COMMERCIAL BUILDINGS:
 FLOOR PLAN
  
 PLEASE PROVIDE UNDER THE R2 OCCUPANCY WHICH OF THE USES
 BELOW:
 APARTMENTS
 BOARDING HOUSES (NONTRANSIENT) WITH MORE THAN 16
 OCCUPANTS
 CONGREGATE LIVING FACILITIES (NONTRANSIENT) WITH MORE
 THAN 16 OCCUPANTS
 HOTELS (NONTRANSIENT)
  
 1C) THERE IS A DISCREPANCY IN THE SCOPE OF WORK BETWEEN
 THE PERMIT APPLICATION AND THE SHEET S1. SHEET S1 DOES
 NOT LIST THE REPLACEMENT OF ANY WINDOWS, WHERE AS THE
 PERMIT APPLICATION DOES INDICATE NEW WINDOWS. NO
 PRODUCT APPROVALS FOR WINDOWS HAVE BEEN SUBMITTED TO
 DATE.
 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. / 2014
 FBC-B 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1
 COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF
 PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS:
 (31)(B) WINDOWS
  
 1D) UNDER COMMENT 1B, THE REQUESTED FLOOR PLAN IS FOR
 THE REPLACEMENT OF WINDOWS, SHOW SIZES OF WINDOWS FOR
 ALL ROOMS, USE OF ROOMS, THE EXISITNG WINDOW AND THE
 TYPE OF PROPOSED WINDOW. PLEASE SHOW COMPLIANCE WITH:
 2014 FBC-B:
  
 1D)(1) 1029.2 MINIMUM SIZE. EMERGENCY ESCAPE AND RESCUE
 OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7
 SQUARE FEET (0.53 M2).
 EXCEPTION: THE MINIMUM NET CLEAR OPENING FOR GRADEFLOOR
 EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE 5 SQUARE
 FEET (0.46 M2).
  
 1D)(2) 1029.2.1 MINIMUM DIMENSIONS. THE MINIMUM NET
 CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 INCHES (610
 MM). THE MINIMUM NET CLEAR OPENING WIDTH DIMENSION
 SHALL BE 20 INCHES (508 MM). THE NET CLEAR OPENING
 DIMENSIONS SHALL BE THE RESULT OF NORMAL OPERATION OF
 THE OPENING.
  
 1D)(3) 1029.3 MAXIMUM HEIGHT FROM FLOOR. EMERGENCY
 ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE
 CLEAR OPENING NOT GREATER THAN 44 INCHES (1118 MM)
 MEASURED FROM THE FLOOR.
  
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved