| 2ND REVIEW |
| DATE: 6/22/16 |
| ACTION: DENIED |
| |
| 1. ALL PROPOSED DOORS ARE TO BE INSTALLED IN RATED |
| CORRIDORS. PROVIDE DOCUMENTATION THAT DOORS WILL COMPLY |
| WITH THE FOLLOWING REQUIREMENTS: |
| |
| 716.5.3 DOOR ASSEMBLIES IN CORRIDORS AND SMOKE |
| BARRIERS. |
| FIRE DOOR ASSEMBLIES REQUIRED TO HAVE A MINIMUM FIRE |
| PROTECTION RATING OF 20 MINUTES WHERE LOCATED IN |
| CORRIDOR WALLS OR SMOKE BARRIER WALLS HAVING A |
| FIRE-RESISTANCE RATING IN ACCORDANCE WITH TABLE 716.5 |
| SHALL BE TESTED IN ACCORDANCE WITH NFPA 252 OR UL 10C |
| WITHOUT THE HOSE STREAM TEST. |
| |
| 716.5 FIRE DOOR AND SHUTTER ASSEMBLIES. |
| APPROVED FIRE DOOR AND FIRE SHUTTER ASSEMBLIES SHALL BE |
| CONSTRUCTED OF ANY MATERIAL OR ASSEMBLY OF COMPONENT |
| MATERIALS THAT CONFORMS TO THE TEST REQUIREMENTS OF |
| SECTION 716.5.1, 716.5.2 OR 716.5.3 AND THE FIRE |
| PROTECTION RATING INDICATED IN TABLE 716.5. FIRE DOOR |
| FRAMES WITH TRANSOM LIGHTS, SIDELIGHTS OR BOTH SHALL BE |
| PERMITTED IN ACCORDANCE WITH SECTION 716.5.6. FIRE DOOR |
| ASSEMBLIES AND SHUTTERS SHALL BE INSTALLED IN |
| ACCORDANCE WITH THE PROVISIONS OF THIS SECTION AND NFPA |
| 80. |
| |
| 716.5.7.1 FIRE DOOR LABELING REQUIREMENTS. |
| FIRE DOORS SHALL BE LABELED SHOWING THE NAME OF THE |
| MANUFACTURER OR OTHER IDENTIFICATION READILY TRACEABLE |
| BACK TO THE MANUFACTURER, THE NAME OR TRADEMARK OF THE |
| THIRD PARTY INSPECTION AGENCY, THE FIRE PROTECTION |
| RATING AND, WHERE REQUIRED FOR FIRE DOORS IN INTERIOR |
| EXIT STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS BY |
| SECTION 716.5.5, THE MAXIMUM TRANSMITTED TEMPERATURE |
| END POINT. SMOKE AND DRAFT CONTROL DOORS COMPLYING WITH |
| UL 1784 SHALL BE LABELED AS SUCH AND SHALL ALSO COMPLY |
| WITH SECTION 716.5.7.3. LABELS SHALL BE APPROVED AND |
| PERMANENTLY AFFIXED. THE LABEL SHALL BE APPLIED AT THE |
| FACTORY OR LOCATION WHERE FABRICATION AND ASSEMBLY ARE |
| PERFORMED. |
| |
| 2. COMPLY WITH FIRE REVIEW COMMENTS. |
| |