2016-08-15 15:31:55 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL |
| BUILDING PLANS EXAMINER |
| [email protected] |
| 561-805-6724 |
| |
| 1. IT IS NOT CLEAR WHERE THE NEW UNNUMBERED STAIR |
| DISCHARGES (SEE SECOND FLOOR PLAN, FIRST FLOOR PLAN). |
| INTERIOR BUILDING PERMIT 16070715 INCLUDES DETAILS FOR |
| STAIR 5, BUT THE DETAILS SHOW A WALL WITH A SINGLE DOOR |
| EXIT DISCHARGE, AND THE STAIR IDENTIFICATION NUMBERS |
| WERE REMOVED FROM THE PLAN ON THE LIFE SAFETY SHEETS |
| (ON PERMIT 16070715 WHICH IS NOT BEING REVIEWED AT THIS |
| TIME BUT WAS CHECKED FOR CLARIFICATION), FBC 107. |
| |
| IF A PROVISO IS NEGOTIATED WITH FIRE, PLEASE ADVISE. |
| |
| 2. AS301, LEVEL 1, THE ACCESSIBLE ROUTE FOR THE |
| ACCESSIBLE VAN PARKING SPACE IS NOT CLEAR. I WAS UNABLE |
| TO LOCATE A DOOR LEADING FROM THE GARAGE AREA TO THE |
| WEST ELEVATORS TO ACCESS THE SALES MANAGEMENT AREA ON |
| THE SECOND FLOOR, SEE FBC 5TH EDITION ACCESSIBILITY |
| 208.2.4, 502.2. NOTE THAT IT APPEARS THAT THE REQUIRED |
| NUMBER OF VAN PARKING SPACES MAY BE EXCEEDED. |
| |
| 3. SHEET AS212A, DOORS TO LOBBY FROM POOL AREA SWING |
| AGAINST PATH OF TRAVEL, FBC 1008.1.2. THIS WAS CORRECT |
| IN THE FIRST REVIEW, REVISED IN THE SECOND REVIEW BUT |
| NOT CLOUDED. PLEASE BE ADVISED THAT, IN GENERAL, ONLY |
| CLOUDED CHANGES ARE REVIEWED. |
| |
| 4. ADVISORY; SHEET AS203, THE SOUTH ACCESSIBLE PARKING |
| SPACE (GRIDLINE G4) REQUIRES THE OCCUPANT TO TRAVEL |
| BEHIND THE VAN PARKING SPACE TO ACCESS THE LOBBY, AVIS, |
| AND RESIDENTIAL LOBBY. THIS WILL BE REQUIRED TO BE |
| CORRECTED ON THE BUILDING PERMIT. |
| |
| 5. THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING |
| PROVISOS: |
| |
| A. PROVISO: TCO AT EACH PHASE IS SUBJECT TO APPROVAL OF |
| THE BUILDING OFFICIAL (OR HIS REPRESENTATIVE) AND FIRE |
| DEPARTMENT, AND MAY INCLUDE ITEMS NOT WITHIN THE SCOPE |
| OF THIS REVIEW. |
| |
| A TCO REQUEST FORM AND FEE WILL BE REQUIRED. THIS FORM |
| IS AVAILABLE UPON REQUEST BY EMAIL. |
| |
| B. PROVISO, LIFE SAFETY PLANS REFER TO LIFE SAFETY |
| SYSTEMS DETAILED ON FMEP SHEETS (LIFE SAFETY TCO NOTES) |
| WHICH HAVE NOT BEEN PROVIDED AT THIS TIME. COMPLIANCE |
| WITH ALL LIFE SAFETY AND ACCESSIBILITY REQUIREMENTS IS |
| REQUIRED FOR EACH PHASE. FMEP SHEETS AND LIFE SAFETY |
| SYSTEM SPECIFICS WILL BE REVIEWED AT TIME OF INTERIOR |
| BUILDOUT PERMIT APPLICATION. |
| |
| C. PROVISO, PERMIT WILL BE ISSUED AT CONTRACTOR'S RISK. |
| FBC105.13 PHASED PERMIT APPROVAL. AFTER SUBMITTAL OF |
| THE APPROPRIATE CONSTRUCTION DOCUMENTS, THE BUILDING |
| OFFICIAL IS AUTHORIZED TO ISSUE A PERMIT FOR THE |
| CONSTRUCTION OF FOUNDATIONS OR ANY OTHER PART OF A |
| BUILDING OR STRUCTURE BEFORE THE CONSTRUCTION DOCUMENTS |
| FOR THE WHOLE BUILDING OR STRUCTURE HAVE BEEN |
| SUBMITTED. THE HOLDER OF SUCH PERMIT FOR THE FOUNDATION |
| OR OTHER PARTS OF A BUILDING OR STRUCTURE SHALL PROCEED |
| AT THE HOLDER 'S OWN RISK WITH THE BUILDING OPERATION |
| AND WITHOUT ASSURANCE THAT A PERMIT FOR THE ENTIRE |
| STRUCTURE WILL BE GRANTED. CORRECTIONS MAY BE REQUIRED |
| TO MEET THE REQUIREMENTS OF THE TECHNICAL CODES. THIS |
| PROVISION IS ONLY FOR THE FLORIDA BUILDING CODE, ALL |
| OTHER AGENCY APPROVALS NECESSARY FOR CONSTRUCTION MUST |
| BE SECURED PRIOR TO THIS PROVISION BEING APPLIED. |
| |
| D. INFORMATIONAL ONLY, A CURSORY REVIEW HAS BEEN |
| PERFORMED ON THE LIFE SAFETY PLAN AND ACCESSIBILITY. |
| DIMENSIONS, DOOR TYPES, HARDWARE SCHEDULE, ETC. IS |
| REQUIRED FOR A COMPREHENSIVE REVIEW WHICH WILL BE |
| PERFORMED AT TIME OF INTERIOR BUILDOUT PERMIT REVIEW. |
| |
| E. PROVISO, THIS STUCTURE SERVES A BUILDING WHICH HAS |
| NOT BEEN REVIEWED BY THIS DEPARTMENT (TRAIN STATION). |
| ACCESSIBLE ROUTE IN COMPLIANCE WITH FBC 5TH EDITION |
| ACCESSIBILITY IS REQUIRED AND WILL BE VERIFIED IN THE |
| FIELD. |
| |
| |