Plan Review Notes
Plan Review Notes For Permit 16040430
Permit Number 16040430
Review Stop P
Sequence Number 2
Notes
Date Text
2016-07-23 12:03:071) SECONDARY (EMERGENCY) ROOF DRAINS OR SCUPPERS ARE
 REQUIRED PER 2014 FPC SEC. 1108. IF SCUPPERS ARE
 SUPPLIED, COMPLY WITH TABLE 1106.7 OF THE FPC.
 2) WASHING MACHINE DRAIN IS UNDERSIZED & NOT VENTED.
 2014 FBCR SEC. P3201.7, P3101.2.
 3) SHOWER IN CABANA BATH NOT PROPERLY VENTED. 2014 FBCR
 SEC. P3201.7, P3101.2.
 4) SHOWER IN HIS BATH NOT PROPERLY VENTED. 2014 FBCR
 SEC. P3201.7, P3101.2.
 5) WET VENT FOR HER BATH IS UNDERSIZED. 2014 FBCR SEC.
 P3108.3.
 6) SIZE ALL VENTS ON THE SANITARY RISER.
 7) SINK IN SUMMER KITCHEN NOT ON SANITARY RISER.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  