Date |
Text |
2016-04-26 13:36:33 | |
| 1ST REVIEW: FBC 2014 |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| 561-805-6711 |
| [email protected] |
| |
| PLUMBING COMMENTS: |
| |
| 1. TWO DRINKING FOUNTAINS REQUIRED. PER FBC ACC. SEC. |
| 211.2 MINIMUM NUMBER. |
| NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED. |
| ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH |
| 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH |
| 602.7. |
| |
| 2. SHT.A-202 |
| (A) DETAIL #2 SHOWS LAVATORY ENCROACHING ON CLEAR |
| FLOORSPACE FOR TOILET IT SHALL COMPLY TO FBC ACC. SEC. |
| 604.3.1 |
| |
| (B) DETAIL #3 SHOW COMPLIANCE WITH FBC ACC. SEC. |
| |
| 608.3.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS. |
| WHERE A SEAT IS PROVIDED IN STANDARD ROLL-IN TYPE |
| SHOWER COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THE |
| BACK WALL AND THE SIDE WALL OPPOSITE THE SEAT. GRAB |
| BARS SHALL NOT BE PROVIDED ABOVE THE SEAT. WHERE A SEAT |
| IS NOT PROVIDED IN STANDARD ROLL-IN TYPE SHOWER |
| COMPARTMENTS, GRAB BARS SHALL BE PROVIDED ON THREE |
| WALLS. GRAB BARS SHALL BE INSTALLED 6 INCHES (150 MM) |
| MAXIMUM FROM ADJACENT WALLS. |
| . |
| 609.4 POSITION OF GRAB BARS. |
| GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS FOR |
| CHILDREN?S USE COMPLYING WITH 604.9, GRAB BARS SHALL BE |
| INSTALLED IN A HORIZONTAL POSITION 18 INCHES (455 MM) |
| MINIMUM AND 27 INCHES (685 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. THE |
| HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A |
| BATHTUB SHALL COMPLY WITH 607.4.1.1 OR 607.4.2.1. |
| |
| 610.3 SHOWER COMPARTMENT SEATS. |
| WHERE A SEAT IS PROVIDED IN A STANDARD ROLL-IN SHOWER |
| COMPARTMENT, IT SHALL BE A FOLDING TYPE, SHALL BE |
| INSTALLED ON THE SIDE WALL ADJACENT TO THE CONTROLS, |
| AND SHALL EXTEND FROM THE BACK WALL TO A POINT WITHIN 3 |
| INCHES (75 MM) OF THE COMPARTMENT ENTRY. WHERE A SEAT |
| IS PROVIDED IN AN ALTERNATE ROLL-IN TYPE SHOWER |
| COMPARTMENT, IT SHALL BE A FOLDING TYPE, SHALL BE |
| INSTALLED ON THE FRONT WALL OPPOSITE THE BACK WALL, AND |
| SHALL EXTEND FROM THE ADJACENT SIDE WALL TO A POINT |
| WITHIN 3 INCHES (75 MM) OF THE COMPARTMENT ENTRY. IN |
| TRANSFER-TYPE SHOWERS, THE SEAT SHALL EXTEND FROM THE |
| BACK WALL TO A POINT WITHIN 3 INCHES (75 MM) OF THE |
| COMPARTMENT ENTRY. THE TOP OF THE SEAT SHALL BE 17 |
| INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM |
| ABOVE THE BATHROOM FINISH FLOOR. SEATS SHALL COMPLY |
| WITH 610.3.1 OR 610.3.2. |
| |
| 610.3.2 L-SHAPED SEATS. |
| THE REAR EDGE OF AN L-SHAPED SEAT SHALL BE 2 1/2 INCHES |
| (64 MM) MAXIMUM AND THE FRONT EDGE 15 INCHES (380 MM) |
| MINIMUM AND 16 INCHES (405 MM) MAXIMUM FROM THE SEAT |
| WALL. THE REAR EDGE OF THE ?L? PORTION OF THE SEAT |
| SHALL BE 11/2 INCHES (38 MM) MAXIMUM FROM THE WALL AND |
| THE FRONT EDGE SHALL BE 14 INCHES (355 MM) MINIMUM AND |
| 15 INCHES (380 MM) MAXIMUM FROM THE WALL. THE END OF |
| THE ?L? SHALL BE 22 INCHES (560 MM) MINIMUM AND 23 |
| INCHES MAXIMUM (585 MM) FROM THE MAIN SEAT WALL. |
| |
| 608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS. |
| IN STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS, THE |
| CONTROLS, FAUCETS, AND SHOWER SPRAY UNIT SHALL BE |
| LOCATED ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 |
| INCHES (1220 MM) ABOVE THE SHOWER FLOOR. WHERE A SEAT |
| IS PROVIDED, THE CONTROLS, FAUCETS, AND SHOWER SPRAY |
| UNIT SHALL BE INSTALLED ON THE BACK WALL ADJACENT TO |
| THE SEAT WALL AND SHALL BE LOCATED 27 INCHES (685 MM) |
| MAXIMUM FROM THE SEAT WALL. |
| |
| (C) DETAIL # 4 SHOW COMPLIANCE WITH MIN. AND MAX. PER |
| FBC ACC. SEC. |
| |
| 609.4 POSITION OF GRAB BARS. MEASURED TO TOP OF |
| GRIPPING SURFACE |
| GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| THE GRIPPING SURFACE, EXCEPT THAT AT WATER CLOSETS FOR |
| CHILDREN?S USE COMPLYING WITH 604.9, GRAB BARS SHALL BE |
| INSTALLED IN A HORIZONTAL POSITION 18 INCHES (455 MM) |
| MINIMUM AND 27 INCHES (685 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. THE |
| HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A |
| BATHTUB SHALL COMPLY WITH 607.4.1.1 OR 607.4.2.1. |
| |
| 604.7 DISPENSERS. |
| TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL |
| NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES |
| NOT ALLOW CONTINUOUS PAPER FLOW. |
| |
| 604.4 SEATS. |
| THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH |
| FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES |
| (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS |
| SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. |
| |
| 604.2 LOCATION. |
| THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR |
| PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE |
| OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM |
| TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR |
| PARTITION, EXCEPT THAT THE WATER CLOSET SHALL BE 17 |
| INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM |
| FROM THE SIDE WALL OR PARTITION IN THE AMBULATORY |
| ACCESSIBLE TOILET COMPARTMENT SPECIFIED IN 604.8.2. |
| WATER CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR |
| RIGHT-HAND APPROACH. |
| |
| 606.3 HEIGHT. |
| LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT |
| OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES |
| (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| |
| |
| 3. PROVIDE MANUFACTURE SPECS FOR WATER HEATER. PER WPB |
| AMEND. TO FBC SEC. 107.2.1 |
| |
| 4. PROVIDE BACK FLOW FOR HUMIDIFIER PER FBC PL SEC. |
| 608.3 |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |