 1ST REVIEW: FBC 2014 BUILDING
 PERMIT #16031101
 3/24/16
  
 1) THE CALULATED PRESSURES FOR ZONE 3 AT -56.3 ARE TOO
 LOW BASED ON TABLE 301.2(2) FBC-14 RESIDENTIAL, AND
 FIGURE 30.4-2.A ASCE 7- 10 WHICH INDICATES THE PARAPET
 SHALL BE MINIMUM 3' HIGH FOR ZONE 3 TO BE TREATED AS
 ZONE 2. PLEASE REVISE THE CALCULATIONS AND ENHANCED
 NAILING SPECIFICATIONS.
 2) INDICATE ON THE APPLICATION HOW MANY SQUARE FEET OF
 FLAT ROOF AND HOW MANY SQUARE FEET OF SLOPED.
  