Date |
Text |
2016-03-18 16:09:28 | 1ST REVIEW: FBC 2014 5TH ED |
| CHRISTOPHER S. THROOP, C.B.O. |
| BLDG. PLANS EXAMINER ? PX3169 |
| (561) 805-6718 |
| [email protected] |
| |
| 1. PROVIDE DETAIL FOR WINDOW OPENINGS TO B ENCLOSED. |
| 2. PROVIDE FLOOR PLAN WITH THE FOLLOWING: EXIT ACCESS |
| PER FBC 1014.1, EXIT PASSAGEWAY WIDTH PER FBC 1023, |
| EXIT SIGNS PER FBC 1011, EXIT PATH OF TRAVEL PER TABLE |
| 1016.2, EXIT DOORS COMPLYING WITH FBC 1008.1.1 AND EXIT |
| ILLUMINATION PER FBC 1011.3. |
| MULTIPLE DEMENSIONS MISSING ON STAIR DETAILS: LANDING |
| WIDTH AT EXIT DOOR - FBC 1008.1.6, STAIRWAY LANDING PER |
| FBC 1009.8, EXIT DOORS PER FBC 1008.1.1, HANDRAIL |
| DETAIL PER FBC 1012.3 AND HANDRAIL EXTENSIONS PER FBC |
| 1012.6. |
| 3. DETAIL A, PG A-1.01 SHOWS A FENCE IN THE PATH OF |
| TRAVEL AT STAIR LANDING. |
| |
| FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE |
| DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH |
| INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES |
| SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE |
| TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE |
| FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE |
| DESIGN. (SEE ALSO SECTION 107.3.5). |
| |
| |
| |