2016-08-09 17:47:44 | |
| RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING |
| REVIEW CHECKLIST. |
| CODE: FBC-5TH EDITION (2014). |
| |
| ORIGINAL COMMENT: |
| 1- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| R101.4.3 OF FBC-ENERGY CONSERVATION, 5TH EDITION |
| (2014). |
| RESPONSE: |
| REPEAT COMMENT. NOT ADDRESSED. PERMIT CAN NOT BE ISSUED |
| WITHOUT THE ENERGY CALCULATIONS. SEC. R103.1.1.2 |
| FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| ORIGINAL COMMENT: |
| 2- DOORS AND WINDOWS DESIGN PRESSURES SHOWN ON SHEET |
| A-7 DON'T MATCH DESIGN PRESSURES SPECIFIED ON SHEET |
| A-2. REVISE AS REQUIRED. SEC. R301 OF FBC-RESIDENTIAL, |
| 5TH EDITION (2014). |
| RESPONSE: |
| THE DESIGN PRESSURES WERE DELETED FROM SHEET A-2. THOSE |
| DESIGN PRESSURES WERE CORRECT. THEY CORRESPONDED TO |
| EXPOSURE "C". THE DESIGN PRESSURES SHOWN ON SHEET A-7 |
| DON'T CORRESPOND TO EXPOSURE "C". ALSO, THE DESIGN |
| PRESSURES ON THE SMALL OPENINGS CAN NOT BE LOWER THAN |
| THE BIGGER OPENINGS. THE SMALLER THE TRIBUTARY AREA, |
| THE HIGHER THE DESIGN PRESSURES. REVISE ALL THE DESIGN |
| PRESSURES SHOWN ON SHEET A-7. NOTE: MAKE SURE DESIGN |
| PRESSURES ARE GIVEN BASED ON THE OPENING SIZE AND |
| DISTANCE FROM THE EDGE OF BUILDING. FIGURE R301.2(7) |
| REQUIRES 4'-0" MINIMUM AS THE EDGE DISTANCE FOR ALL |
| CASES. |
| |
| ORIGINAL COMMENT: |
| 3- PROVIDE COMPLETE WALL SECTION THRU GABLE END SHOWING |
| COMPLIANCE WITH SEC. R609.4 OF FBC-RESIDENTIAL, 5TH |
| EDITION (2014). |
| RESPONSE: |
| RESPONSE LETTER STATED THAT "MASONRY WALL IS EXISTING". |
| THIS IS NOT CORRECT. THE WEST GABLE END WALL BY THE |
| KITCHEN AREA IS NEW. THE "PERSPECTIVE OF GABLE END |
| TRUSS" DETAIL SHOWN ON SHEET A-6 DOESN'T MATCH TRUSS |
| PLAN SHOWN ON SAME SHEET. THERE IS NO GABLE END TRUSS. |
| THERE ARE NOT CONNECTORS SPECIFIED FOR THE 2X4 |
| OUTRIGGERS. THERE ARE NOT GABLE END VERTICAL WEBS |
| LARGER THAN 4'-0". THEREFORE THE VERTICAL REINFORCEMENT |
| WOULDN'T APPLY. SEC. R609.4 OF FBC-RESIDENTIAL REQUIRES |
| CONCRETE BLOCK WALL TO BE CONTINUOUS TO THE ROOF LINE. |
| OTHERWISE, WOOD FRAME CONSTRUCTION REQUIRES CONFORMANCE |
| WITH TABLES R609.4A AND R609.4B AND FIGURE R609.4. SEE |
| EXCEPTION FOR SEC. R609.4. PROVIDE A COMPLETE |
| SECTION/DETAIL SHOWING HOW PROVIDING A CONTINUOUS LOAD |
| PATH FROM THE ROOF TO THE CONCRETE BLOCK WALL. SPECIFY |
| ALL CONNECTORS AS REQUIRED BY SEC. R801.2 |
| |
| 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| FAC 61G20-3.002(33) FOR: |
| A) FIXED WINDOWS AS SHOWN ON PLANS. NONE SUBMITTED AT |
| THIS TIME. |
| |
| ORIGINAL COMMENT: |
| B) INSWING ENTRY DOOR AS SHOWN ON PLANS. |
| |
| RESPONSE: |
| THERE ARE TWO DIFFERENT PRODUCT APPROVALS SUBMITTED. |
| NONE OF THEM MATCH SINGLE INSWING DOOR TYPE AS SHOWN ON |
| PLANS. BOTH PRODUCT APPROVALS ARE FOR DOUBLE DOORS OR |
| SINGLE DOOR WITH SIDELITE. NOT SINGLE DOORS ONLY. |
| PROVIDE PRODUCT APPROVAL THAT MATCHES PLANS AND DOOR |
| SCHEDULE. |
| |
| NOTE: DOOR SCHEDULE ON SHEET A-8 DOESN'T MATCH |
| INFORMATION SHOWN ON PLANS. REVISE AS REQUIRED TO |
| MATCH. |
| |
| ORIGINAL COMMENT: |
| C) SHUTTERS IF DOORS AND WINDOWS DON'T HAVE IMPACT |
| GLASS. AND PROVIDE COMPLETE INSTALLATION SCHEDULE. |
| |
| RESPONSE: |
| FRENCH DOORS FLORIDA PRODUCT APPROVAL FL16904-R3 |
| SUBMITTED IS FOR NON-IMPACT DOORS. NEED TO PROVIDE |
| SHUTTERS PRODUCT APPROVAL AND COMPLETE INSTALLATION |
| SCHEDULE. |
| |
| 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| NEW COMMENT: |
| 6- SITE PLAN FOOTPRINT SUBMITTED DOESN'T MATCH PROPOSED |
| FLOOR PLAN ON SHEET A-5. REVISE AS REQUIRED TO MATCH. |
| SEC. 107.2.1 CITY AMENDMENTS. |
| |
| ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| DRAWINGS. SUBMIT OLD DRAWINGS FOR REFERENCE. DON'T |
| STAPLE OLD DRAWINGS. |
| |