Date |
Text |
2016-09-07 14:01:29 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 16030222 |
| ADD: 5400 EAST AVENUE |
| CONT: STUART & SHELBY DEVELOPMENT |
| TEL: 561-637-7902 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 3RD REVIEW |
| DATE: WED. SEPT. 07/ 2016 |
| ACTION: DENIED |
| |
| 1-3) COMPLIED. |
| |
| 4A) 3RD REVIEW. FLOOD ZONE COMMENT. THE CITY IS IN |
| RECEIPT OF THE FLOOD ZONE CERTIFICATE FOR 5400 EAST |
| AVE. SURVEYORS NAME: JAMES G. PEDEN, JR. DATED |
| 6/12/2015. PLEASE NOTE THIS CERTIFICATE IS NOT SIGNED |
| NOR SEALED BY THE SURVEYOR. SURVEYORS: F. S. 472.025 |
| SEALS. THE FINISH FLOOR IS GIVEN AT ELEVATION 17.1 FT. |
| NGVD. |
| |
| 4B) 3RD REVIEW. SCOPE OF PROJECT WAS REDUCED FROM |
| $1,075,000.00 DOLLARS TO $998,616.00 IN VALUE. PLEASE |
| SUBMIT ON THE CONTRACTORS LETTERHEAD AN ITEMIZED LIST |
| AND DOLLAR AMOUNT WHERE THE SCOPE OF WORK WAS REDUCED |
| TO UNDER THE 50% OF THE MARKET VALUE. |
| |
| 2ND REVIEW COMMENT. THE CITY HAS ALSO REVIEWED THE |
| BUILDING EVALUATION REPORT PREPARED BY BOYLE & DRAKE |
| INC. LISTING THE MARKET VALUE OF THE STRUCTURE AT |
| $2,435,000.00 DOLLARS. 50% OF THE MARKET VALUE IS |
| $1,217,500.00 DOLLARS. |
| |
| 4C) THE CITY?S MUNI CODE UNDER THE DEFINITION OF |
| SUBSTANTIAL IMPROVEMENT IS FOUND UNDER ARTICLE XIX |
| DEFINITIONS, SECTION 94-611. |
| SUBSTANTIAL IMPROVEMENT MEANS ANY COMBINATION OF |
| REPAIRS, RECONSTRUCTION, ALTERATION, OR IMPROVEMENTS TO |
| A STRUCTURE, TAKING PLACE DURING THE LIFE OF A |
| STRUCTURE, IN WHICH THE CUMULATIVE COST EQUALS OR |
| EXCEEDS 50 PERCENT OF THE MARKET VALUE OF THE |
| STRUCTURE. THE MARKET VALUE OF THE STRUCTURE SHOULD BE |
| THE APPRAISED VALUE OF THE STRUCTURE PRIOR TO THE START |
| OF THE INITIAL REPAIR OR IMPROVEMENT, OR IN THE CASE OF |
| DAMAGE, THE VALUE OF THE STRUCTURE PRIOR TO THE DAMAGE |
| OCCURRING. FOR THE PURPOSES OF THIS DEFINITION, |
| "SUBSTANTIAL IMPROVEMENT" IS CONSIDERED TO OCCUR WHEN |
| THE FIRST ALTERATION OF ANY WALL, CEILING, FLOOR, OR |
| OTHER STRUCTURAL PART OF THE BUILDING COMMENCES, |
| WHETHER OR NOT THAT ALTERATION AFFECTS THE EXTERNAL |
| DIMENSIONS OF THE STRUCTURE. THE TERM "SUBSTANTIAL |
| IMPROVEMENT" DOES NOT, HOWEVER, INCLUDE ANY IMPROVEMENT |
| OF A STRUCTURE TO COMPLY WITH EXISTING HEALTH, |
| SANITARY, OR SAFETY CODES WHICH ARE SOLELY NECESSARY TO |
| ENSURE SAFE LIVING CONDITIONS. |
| |
| 4D) SINCE SUBSTANTIAL IMPROVEMENT HAS BEEN MET WITH THE |
| RENOVATION PERMIT (01040625/ VALUE OF |
| $150,000.00)TO THIS BUILDING. $1,075,000 (APPLIED |
| PERMIT VALUE) + $150,000.00 = $ 1,225,000.00 WHICH IS |
| GREATER THAN $1,217,500.00 OR 50% OF THE STRUCTURE |
| SUBSTANTIAL IMPROVEMENT HAS BEEN MET. |
| |
| 4E) SINCE IS A COMMERCIAL BUILDING ( NONRESIDENTIAL) |
| FLOOD PROOFING IS A OPTION TO MEET CODE COMPLIANCE. |
| WEST PALM BEACH MUNI CODE: |
| SEC. 94-546 (B) AREAS OF SPECIAL FLOOD HAZARD WITH BASE |
| FLOOD ELEVATION PROVIDED. (2) NONRESIDENTIAL |
| CONSTRUCTION. |
| ALL NEW CONSTRUCTION OR SUBSTANTIAL IMPROVEMENT OF ANY |
| COMMERCIAL, INDUSTRIAL OR OTHER NONRESIDENTIAL |
| STRUCTURE SHALL EITHER HAVE THE LOWEST FLOOR, INCLUDING |
| BASEMENT, ELEVATED TO THE LEVEL OF SIX INCHES ABOVE THE |
| BASE FLOOD ELEVATION OR, TOGETHER WITH ATTENDANT |
| UTILITY AND SANITARY FACILITIES, BE FLOODPROOFED SO |
| THAT BELOW SIX INCHES ABOVE THE FLOOD BASE LEVEL THE |
| STRUCTURE IS WATERTIGHT, WITH WALLS SUBSTANTIALLY |
| IMPERMEABLE TO THE PASSAGE OF WATER AND WITH STRUCTURAL |
| COMPONENTS HAVING THE CAPABILITY OF RESISTING |
| HYDROSTATIC AND HYDRODYNAMIC LOADS AND EFFECTS OF |
| BUOYANCY. A REGISTERED PROFESSIONAL ENGINEER OR |
| ARCHITECT SHALL CERTIFY THAT THE STANDARDS OF THIS |
| SUBSECTION ARE SATISFIED. SUCH CERTIFICATION SHALL BE |
| PROVIDED TO THE CITY ENGINEER. |
| |
| 1ST ROUND COMMENT. 4) PLEASE NOTE THIS PROPERTY IS |
| LOCATED WITHIN AN AH FLOOD ZONE. FBC BUILDING 1612 AND |
| CITY OF WPB CODE OF ORDINANCES SECTION 94-546. |
| STRUCTURE IS LOCATED IN AN "A" FLOOD ZONE. A FLOOD |
| ELEVATION CERTIFICATE WILL BE REQUIRED. PLEASE REVIEW |
| CITY ORDINANCE FOR THE CITY REQUIREMENTS REQUIRE AN |
| ADDITIONAL 6 INCHES OF ELEVATION. |
| |
| DURING THE PERMITTING OF THIS STRUCTURE THERE WILL BE |
| REQUIRED (2) DIFFERENT FLOOD ZONE CERTIFICATES |
| REQUIRED: |
| (1) A FLOOD ZONE CERTIFICATE IS REQUIRED AS PART OF THE |
| PLAN REVIEW DOCUMENTS WITH THE PROPOSED FINISH FLOOR |
| HEIGHT. |
| (2) BEFORE THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY |
| OR A CERTIFICATE OF COMPLETION THE 2ND FLOOD ZONE |
| CERTIFICATE IS REQUIRED WITH THE HEIGHT OF ALL EXTERIOR |
| ATTENDANTS |
| A/C PADS OR OTHER SLABS FOR GENERATORS |
| FEMA FORM OMB NO. 1660-0008 EXPIRES: |
| JULY 31/2015 |
| FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR |
| USE, EFFECTIVE AUGUST 1/ 2013, THROUGH JULY 31/ 2015. |
| FORM. ADDITIONAL INFORMATION ON THE DIFFERENCES, THE |
| NEW FORM, AND INSTRUCTIONS ARE AVAILABLE AT: |
| HTTP://WWW.FEMA.GOV/BUSINESS/NFIP/ELVINST.SHTM |
| |
| 5-8) COMPLIED. |
| |
| 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION |
| DEVELOPMENT SERVICES DEPARTMENT |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |