2016-03-08 13:34:47 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 16030163 |
| ADD: 206 DYER RD. |
| CONT: STORM ROOFING |
| TEL: 561-689-0268 |
| E-MAIL: [email protected] |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. MARCH 08/2016 |
| ACTION: DENIED |
| |
| 1) PLEASE SHOW COMPLIANCE WITH: |
| 2014 FBC-EXISTING BUILDING CODE 708.8 WHEN A ROOF |
| COVERING ON AN EXISTING SITE-BUILT SINGLE FAMILY |
| RESIDENTIAL STRUCTURE IS REMOVED AND REPLACED ON A |
| BUILDING THAT IS LOCATED IN THE WIND-BORNE DEBRIS |
| REGION AS DEFINED IN THE FLORIDA BUILDING CODE, |
| BUILDING AND THAT HAS AN INSURED VALUE OF $300,000 OR |
| MORE OR, IF THE BUILDING IS UNINSURED OR FOR WHICH |
| DOCUMENTATION OF INSURED VALUE IS NOT PRESENTED, HAS A |
| JUST VALUATION FOR THE STRUCTURE FOR PURPOSES OF AD |
| VALOREM TAXATION OF $300,000 OR MORE: |
| |
| (A) ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS |
| REQUIRED BY SECTION 708.8.1. |
| |
| (B) MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION |
| SHALL NOT BE REQUIRED BEYOND A 15-PERCENT INCREASE IN |
| THE COST OF REROOFING. |
| |
| EXCEPTION: SINGLE-FAMILY RESIDENTIAL STRUCTURES |
| PERMITTED SUBJECT TO THE FLORIDA BUILDING CODE ARE NOT |
| REQUIRED TO COMPLY WITH THIS SECTION. |
| |
| 708.8.1 ROOF-TO-WALL CONNECTIONS FOR SITE-BUILT SINGLE |
| FAMILY RESIDENTIAL STRUCTURES. |
| WHERE REQUIRED BY SECTION 708.8, THE INTERSECTION OF |
| ROOF FRAMING WITH THE WALL BELOW SHALL PROVIDE |
| SUFFICIENT RESISTANCE TO MEET THE UPLIFT LOADS |
| SPECIFIED IN TABLE 708.8.1, EITHER BECAUSE OF EXISTING |
| CONDITIONS OR THROUGH RETROFIT MEASURES. AS AN |
| ALTERNATIVE TO AN ENGINEERED DESIGN, THE PRESCRIPTIVE |
| RETROFIT SOLUTIONS PROVIDED IN SECTIONS 708.8.1.1 |
| THROUGH 708.8.1.7 SHALL BE ACCEPTED AS MEETING THE |
| MANDATED ROOF-TO-WALL RETROFIT REQUIREMENTS. |
| EXCEPTIONS: |
| |
| 1. WHERE IT CAN BE DEMONSTRATED (BY CODE ADOPTION DATE |
| DOCUMENTATION AND PERMIT ISSUANCE DATE) THAT |
| ROOF-TO-WALL CONNECTIONS AND/OR ROOF-TO FOUNDATION |
| CONTINUOUS LOAD PATH REQUIREMENTS WERE REQUIRED AT THE |
| TIME OF ORIGINAL CONSTRUCTION. |
| |
| 2. ROOF-TO-WALL CONNECTIONS SHALL NOT BE REQUIRED |
| UNLESS EVALUATION AND INSTALLATION OF CONNECTIONS AT |
| GABLE ENDS OR ALL CORNERS CAN BE COMPLETED FOR 15 |
| PERCENT OF THE COST OF ROOF REPLACEMENT. |
| |
| JAMES A. WITMER CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION |
| DEVELOPMENT SERVICES DEPARTMENT |
| TEL: 561-805-6715 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| DEVELOPMENT SERVICES HOME PAGE |
| HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| |
| PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| |
| MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| |
| |