Date |
Text |
2016-03-09 15:58:23 | 1ST REVIEW: FBC 2014 5TH ED |
| CHRISTOPHER S. THROOP, C.B.O. |
| BLDG. PLANS EXAMINER ? PX3169 |
| (561) 805-6718 |
| [email protected] |
| |
| 1. PROVIDE DETAIL FOR CMU INFILL WALL AT GARAGE DOOR |
| OPENING. INCLUDE VERTICAL AND HORIZONTAL RE-INFORCING |
| AND CONNECTION TO EXISTING SLAB AND BEAM. |
| |
| FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR |
| TEST REPORTS AS PROOF OF COMPLIANCE PLEASE BE ADVISED |
| THE INSPECTOR MAY REQUIRE PREVIOUSLY COMPLETED WORK TO |
| BE MADE ACCESSIBLE AND OPEN FOR INSPECTION OR REQUIRE |
| ADDITIONAL DOCUMENTATION FOR ALL CONCEALED WORK |
| PREVIOUSLY COMPLETED PURSUANT TO FBC 110 & FBC 117. |
| FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A |
| PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY |
| THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK |
| SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION |
| PURPOSES UNTIL APPROVED. |
| REQUIRED TESTS ARE TO BE MADE AT THE EXPENSE OF THE |
| OWNER, OR AGENT, BY AN APPROVED TESTING LABORATORY OR |
| OTHER APPROVED AGENCY. |
| |
| 2. PROVIDE PRODUCT APPROVALS FOR IMPACT FIXED GLASS. |
| |
| FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| SPECIFICALLY, PROVIDE WINDOW SUBMITTALS. |
| |
| 3. BASED ON THE REQUIREMENTS OF THE EXISTING BUILDING |
| CODE, SEC R322, IT MUST BE ESTABLISHED WHAT LEVEL OF |
| WORK WILL BE REQUIRED. PROVIDE DOCUMENTATION |
| ESTABLISHING "MARKET VALUE" OF THE RESIDENCE SO IT CAN |
| BE DETERMINED IF THE PROPOSED IMPROVEMENTS EXCEED 50% |
| OF MARKET VALUE. THE LEVEL OF WORK REQUIRED WILL BE |
| DETERMINED BY THIS INFORMATION. SEE BELOW. |
| |
| [B] 402.2 FLOOD HAZARD AREAS. |
| FOR BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS |
| ESTABLISHED IN SECTION 1612.3 OF THE FLORIDA BUILDING |
| CODE, BUILDING OR SECTION R322 OF THE FLORIDA BUILDING |
| CODE, RESIDENTIAL, AS APPLICABLE, ANY ADDITION THAT |
| CONSTITUTES SUBSTANTIAL IMPROVEMENT OF THE EXISTING |
| STRUCTURE, AS DEFINED IN SECTION 202, SHALL COMPLY WITH |
| THE FLOOD DESIGN REQUIREMENTS FOR NEW CONSTRUCTION, AND |
| ALL ASPECTS OF THE EXISTING STRUCTURE SHALL BE BROUGHT |
| INTO COMPLIANCE WITH THE REQUIREMENTS FOR NEW |
| CONSTRUCTION FOR FLOOD DESIGN. |
| |
| FOR BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS |
| ESTABLISHED IN SECTION 1612.3 OF THE FLORIDA BUILDING |
| CODE, BUILDING, OR SECTION R322 OF THE FLORIDA BUILDING |
| CODE, RESIDENTIAL, AS APPLICABLE ANY ADDITIONS THAT DO |
| NOT CONSTITUTE SUBSTANTIAL IMPROVEMENT OF THE EXISTING |
| STRUCTURE, AS DEFINED IN SECTION 202, ARE NOT REQUIRED |
| TO COMPLY WITH THE FLOOD DESIGN REQUIREMENTS FOR NEW |
| CONSTRUCTION. |
| |
| FBC 202 |
| SUBSTANTIAL IMPROVEMENT. ANY REPAIR, RECONSTRUCTION, |
| REHABILITATION, ALTERATION, ADDITION OR OTHER |
| IMPROVEMENT OF A BUILDING OR STRUCTURE, THE COST OF |
| WHICH EQUALS OR EXCEEDS 50 PERCENT OF THE MARKET VALUE |
| OF THE STRUCTURE BEFORE THE IMPROVEMENT OR REPAIR IS |
| STARTED. IF THE STRUCTURE HAS SUSTAINED SUBSTANTIAL |
| DAMAGE, ANY REPAIRS ARE CONSIDERED SUBSTANTIAL |
| IMPROVEMENT REGARDLESS OF THE ACTUAL REPAIR WORK |
| PERFORMED. |
| |
| |