Plan Review Notes
Plan Review Notes For Permit 16020922
Permit Number 16020922
Review Stop B
Sequence Number 1
Notes
Date Text
2016-02-25 11:30:17PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THERE ARE TWO BUILDINGS ON THIS PROPERTY. INDICATE
 WHICH ONE OF THE BUILDINGS IS TO BE RE-ROOFED.
 FBC107.2.1
  
 2) PROVIDE TWO COPIES OF A ROOF DIAGRAM WITH
 DIMENSIONS, LOCATIONS OF SCUPPERS, ROOF SLOPE, PARAPET
 HEIGHTS ON ALL SIDES AND ANY OTHER RELAVENT
 INFORMATION. FBC 107.2.1
  
 3) THE FASTENER SPACING ON SECTION C OF THE FORM THAT
 YOU SUBMITTED DOES NOT MATCH THE SPACING SPECIFIED ON
 PAGE 23 OF THE NOA. THE MAXIMUM DESIGN PRESSURE ON PAGE
 23 IS NEGATIVE 52.5 PSF. SPECIFY THE REQUIRED DESIGN
 PRESSURES FOR THE THREE ROOF ZONES ON THE ROOF DRAWING.
 IF THE REQUIRED PRESSURES ARE MORE THAN -52.5 PSF, THEN
 SUBMIT SIGNED AND SEALED RAS 117 CALCULATIONS FOR THE
 ENHANCED FASTENING AS REQUIRED BY LIMITATION #7 ON PAGE
 42 OF THE NOA NO.14-0529.02.