Plan Review Notes
Plan Review Notes For Permit 16020831
Permit Number 16020831
Review Stop B
Sequence Number 2
Notes
Date Text
2016-06-17 17:00:44RESIDENTIAL (R3) ALTERATION SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 ORIGINAL COMMENT:
 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF THE PAID RECEIPT IF FEES ARE DUE.
 COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND
 DEVELOPMENT CODE.
 RESPONSE: OK. TALKED TO FRED. NO DOING THE ADDITION.
  
  
  
 2- SHEET D-1:
 ORIGINAL COMMENT:
 A) DRAINAGE PLAN: PROVIDE COMPLIANCE WITH THE OVERFLOW
 SCUPPERS AS REQUIRED BY SEC. R903.4.1 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
 RESPONSE:
 SHEET D-1 WAS REMOVED. SCOPE OF WORK IS NOT CLEAR NOW.
 LEFT SIDE ELEVATION AND REAR ELEVATION ON SHEET A-2
 WERE REVISED. NOW THEY SHOW A PITCHED ROOF AT THE REAR
 PART OF THE BUILDING. BUT, THERE IS A NOTE ON LEFT SIDE
 ELEVATION THAT READS: "EXIST. ROOF TRUSSES TO BE
 REMOVED AND REPLACED W/NEW FLAT DECK ROOF TO MATCH
 EXISTING". IS IT A FLAT ROOF OR PITCHED ROOF? IF
 PITCHED ROOF, THEN SPECIFY ROOF PITCH. ROOF PITCH LESS
 THAN 4;12 REQUIRES TWO LAYERS OF UNDERLAYMENT. ON THE
 OTHER HAND, THE NEW FLAT ROOF NEEDS TO COMPLY WITH THE
 SCUPPERS REQUIREMENTS AS REQUESTED ORIGINALLY. PLEASE
 COORDINATE ALL THE INFORMATION AS REQUIRED TO PROVIDE
 CLEAR SCOPE OF WORK. SEC. 107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 3- ROOF FRAMING PLAN: SPECIFY ALL CONNECTORS FOR
 TRUSSES, ROOF RAFTERS, LEDGERS, BEAMS AND COLUMNS, ETC.
 SEC. R801.2 OF FBC-RESIDENTIAL, 5TH EDITION (2014).
 RESPONSE:
 SHEET D-1 WAS REMOVED. IF THERE ARE ANY NEW ROOF
 TRUSSES, THEN NEED TO PROVIDE ALL THE STRUCTURAL
 INFORMATION. SEC. R301.1 FBC-RESIDENTIAL.
  
 ORIGINAL COMMENT:
 4- PROVIDE COMPLETE SPECIFICATIONS FOR THE ROOF
 SHEATHING ON THE NEW ADDITION AND AREA TO HAVE NEW ROOF
 TRUSSES SHOWING COMPLIANCE WITH THE TYPE OF NAIL AND
 SPACING REQUIRED BY SEC. R803.2.3.1 OF FBC-RESIDENTIAL,
 5TH EDITION (2014).
 RESPONSE:
 SHEET D-1 WAS REMOVED. IF THERE ARE ANY NEW ROOF
 TRUSSES, THEN NEED TO PROVIDE ALL THE STRUCTURAL
 INFORMATION, INCLUDING THE ROOF SHEATHING. SEC. R301.1
 FBC-RESIDENTIAL.
  
 ORIGINAL COMMENT:
 5- DESIGNER OF RECORD TO SPECIFY THE DESIGN PRESSURES
 FOR ALL EXTERIOR DOORS AND WINDOWS. SEC. R301 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
 NOTE: PRODUCT APPROVALS WILL BE REVIEWED WHEN
 INFORMATION IS PROVIDED.
 RESPONSE:
 SCOPE OF WORK IS NOT CLEAR. CLEARLY IDENTIFY WINDOWS
 AND DOORS THAT ARE GOING TO BE REPLACED. NOTE: THERE IS
 A RED TAG ON THIS PROPERTY FOR WORK WITHOUT PERMIT. THE
 SCOPE OF WORK INCLUDES WINDOWS. SEE BELOW FOR RED TAG
 DESCRIPTION:
  
 "PERMITS ARE NEEDED FOR DEMO, FRAMING, WINDOWS, LATH.
 STOP WORK ORDER ISSUED 6/3/15." ISSUED BY BUILDING
 INSPECTOR ART LANGE
  
 ORIGINAL COMMENT:
 6- SPECIFY SIZE AND TYPE OF EXISTING BEDROOM WINDOWS
 AND SPECIFY THE ACTUAL SIZE OF THE PROPOSED CASEMENT
 WINDOW (SEE PRODUCT APPROVAL SUBMITTED) TO VERIFY
 COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. 704 OF
 FBC-EXISTING BUILDING, 5TH EDITION (2014).
 RESPONSE:
 SCOPE OF WORK IS NOT CLEAR. COORDINATE WITH ITEM #5
 ABOVE AND PROVIDE THE REQUIRED INFORMATION ON PLANS.
  
 ORIGINAL COMMENT:
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) CASEMENT WINDOWS SPECIFIED ON PLANS.
 CLARIFY IF BEDROOMS CASEMENT WINDOWS WILL HAVE MULLION
 AS SHOWN ON REAR AND SIDE ELEVATION ON SHEET A-2. NOTE:
 CASEMENT WINDOWS WITH MULLIONS DON'T COMPLY WITH
 EGRESS.
 RESPONSE:
 SCOPE OF WORK IS NOT CLEAR. COORDINATE WITH ITEM #5 AND
 #6 ABOVE AND PROVIDE THE REQUIRED INFORMATION ON PLANS.
  
 B) ARCHED "INSWING" ENTRY DOOR AS SHOWN ON PLANS.
 RESPONSE:
 SCOPE OF WORK IS NOT CLEAR. COORDINATE WITH ITEM #5 AND
 #6 ABOVE AND PROVIDE THE REQUIRED INFORMATION ON PLANS.
  
 C) WINDOW MULLIONS AS SHOWN ON PLANS. AND, SPECIFY SIZE
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES. SEC.
 R301 OF FBC-RESIDENTIAL, 5TH EDITION (2014).
 RESPONSE:
 SCOPE OF WORK IS NOT CLEAR. COORDINATE WITH ITEM #5 AND
 #6 ABOVE AND PROVIDE THE REQUIRED INFORMATION ON PLANS.
  
 D) ALL USP AND SIMPSON STRUCTURAL CONNECTORS SPECIFIED
 ON PLANS AND DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED
 CONNECTOR OR ARCHITECT TO LIST THE FLORIDA PRODUCT
 APPROVAL NUMBER NEXT TO EACH SPECIFIED CONNECTOR.
 RESPONSE:
 SCOPE OF WORK IS NOT CLEAR. COORDINATE WITH ITEM #3
 ABOVE.
  
 ORIGINAL COMMENT:
 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
 RESPONSE:
 SCOPE OF WORK IS NOT CLEAR. COORDINATE WITH ITEM #5 AND
 #6. ARCHITECT TO APPROVE ALL PRODUCT APPROVALS THAT ARE
 GOING TO BE USED. PLEASE REMOVE ANY PRODUCT APPROVAL
 THAT IS NOT GOING TO BE USED.
  
 NOTE: PLANS WILL BE ROUTED TO HISTORIC FOR REVIEW ONCE
 THE REQUIRED CHANGES ARE DONE ON PLANS AND PRODUCT
 APPROVALS TO BE USED ARE IDENTIFIED.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD
 DRAWINGS. SUBMIT OLD DRAWINGS FOR REFERENCE. DON'T
 STAPLE OLD DRAWINGS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]