2016-06-17 11:37:45 | RESIDENTIAL (R3) ADDITION/ALTERATION, THIRD BUILDING |
| REVIEW CHECKLIST. |
| CODE: FBC 5TH EDITION (2014). |
| |
| ORIGINAL COMMENT: |
| 1- PROVIDE ICC EVALUATION REPORT (2 COPIES) FOR ICYNENE |
| INSULATION SPECIFIED ON PLANS. ARCHITECT OF RECORD TO |
| REVIEW AND APPROVE IN WRITING PRIOR TO SUBMITTAL. SEC. |
| R316 OF FBC-RESIDENTIAL, 5TH EDITION (2014), |
| |
| RESPONSE: INSULATION WAS CHANGED TO R30 BATT |
| INSULATION. PROVIDE COMPLETE DETAILS AND SPECIFICATIONS |
| SHOWING HOW COMPLYING WITH THE ROOF VENTILATION SEC. |
| R806 FBC-RESIDENTIAL, 5TH EDITION (2014). REPEAT |
| COMMENT. NOT ADDRESSED. |
| |
| ORIGINAL COMMENT: |
| 2- PROVIDE COMPLETE AND CLEAR INFORMATION FOR WINDOWS |
| AND DOORS. SPECIFY SIZE FOR ALL DOORS AND WINDOWS TO |
| VERIFY COMPLIANCE WITH THE PRODUCT APPROVALS SUBMITTED. |
| . AND SPECIFY SIZE AND TYPE OF EXISTING BEDROOM WINDOWS |
| TO BE REPLACED TO VERIFY COMPLIANCE WITH SEC. 704 OF |
| FBC-EXISTING BUILDING, 5TH EDITION (2014). NOTE: NEW |
| BEDROOM WINDOWS NEED TO COMPLY WITH SEC. R310 OF |
| FBC-RESIDENTIAL, 5TH EDITION (2014), |
| |
| RESPONSE: UNABLE TO VERIFY EGRESS REQUIREMENTS FOR THE |
| FIRST FLOOR MASTER BEDROOM. SIZE SPECIFIED ON PLANS IS |
| NOT LISTED ON THE PRODUCT APPROVAL SUBMITTED. PROVIDE |
| MANUFACTURER'S CUT SHEETS FOR THE SPECIFIED SIZE SHOWN |
| ON FLOOR PLAN AND TYPE OF WINDOW SHOWN ON THE EXTERIOR |
| ELEVATION (UNEQUAL LITES) TO VERIFY COMPLIANCE WITH |
| EGRESS. |
| |
| 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| FAC 61G20-3.002(33) FOR: |
| ORIGINAL COMMENT: |
| A) PRECAST LINTELS AS SPECIFIED ON PLANS. |
| |
| RESPONSE: NOA 14-0903.03 SUBMITTED IS FOR 4", 6" & 12" |
| WIDE LINTELS. THIS IS NOT THE SIZE SPECIFIED ON PLANS. |
| PROVIDE CORRECT PRODUCT APPROVAL FOR 8" LINTELS. |
| |
| ORIGINAL COMMENT: |
| B) GARAGE DOOR THAT MEETS THE DESIGN PRESSURES |
| CALCULATED BY THE ENGINEER OF RECORD. FLORIDA PRODUCT |
| APPROVAL FL15371-R2 SUBMITTED DOESN'T MEET THE DESIGN |
| PRESSURES SHOWN ON SHEET S0.1. |
| |
| RESPONSE: NOT ADDRESSED (TWICE). |
| |
| 4- DESIGNER OF RECORD TO REVIEW AND APPROVE ABOVE |
| PRODUCT APPROVALS AS REQUIRED BY SEC. 107.4.1 CITY |
| AMENDMENTS. |
| |
| ORIGINAL COMMENT: |
| 5- SPECIFY ATTIC ACCESS LOCATION AND SIZE AT NEW GARAGE |
| ADDITION. SEC. R807 OF FBC-RESIDENTIAL, 5TH EDITION |
| (2014). |
| |
| RESPONSE: SIZE WAS NO SPECIFIED. |
| |
| ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| ***PLEASE REMOVE ANY REVISED DRAWING. DON'T STAPLE OLD |
| DRAWINGS TO NEW RESUBMITTED SET. SUBMIT OLD DRAWINGS |
| FOR REFERENCE. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| (561)805-6712 |
| [email protected] |