Plan Review Notes
Plan Review Notes For Permit 16020319
Permit Number 16020319
Review Stop B
Sequence Number 2
Notes
Date Text
2016-03-16 16:25:202014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. MARCH 16/ 2016
 ACTION: DENIED
  
 1) 2ND REQUEST/ SEMI COMPLIED. THE PERMIT APPLICATION
 INDICATES THE WORK TO BE PREFORMED UNDER THIS PERMIT IS
 TO INSTALL A WINDOW AND SHUTTER. THE FLOOR PLAN
 SUBMITTED INDICATES THERE IS A NEW WINDOW(NON-IMPACT/
 NO STORM SHUTTER SUBMITTED FOR THIS OPENING, AND A
 SHUTTER UNDER FOR A SEPARATE OPENING, WHAT APPEARS TO
 BE A DOOR ONTO A PATIO. PLEASE PROVIDE THE SIZE OF EACH
 OF THE OPENINGS (WINDOW AND DOOR) ON THE FLOOR PLAN.
 THE WINDOW IS THIS A REPLACEMENT SAME SIZE SAME TYPE OF
 WINDOW? PLEASE NOTE THIS IS NOT A SINGLE FAMILY
 RESIDENCE BUT A CONDOMINIUM.107.2.1.3 ADDITIONAL
 INFORMATION IS REQUIRED.
  
 2) THE ENGINEERING EXPRESS SHEET SUBMITTED WILL NEED TO
 HAVE A ELECTRONIC SIGNATURE TO BE A VALID ENGINEERING
 SHEET. THE SUBMITTED ENGINEERING SHEET IS FOR THE MORE
 RESTRICTIVE "D" EXPOSURE WITH ASSOCIATED HIGHER
 PRESSURES, PLEASE PROVIDE WHAT THE MEAN ROOF HEIGHT OF
 THIS BUILDING?
  
 WIND DESIGN REQUIREMENTS. 2014 FBC-B 1603.1.4 WIND
 DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 2.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
  
 2.2. RISK CATEGORY.
  
 2.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
  
 2.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 2.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING.
  
 1609.3.1 WIND SPEED CONVERSION VULT TO VASD.
  
 3)SEMI-COMPLIED. UNTIL THE ABOVE COMMENTS ARE SATISFIED
 THE PRESSURES CAN NOT BE VALIDATED. SUBMIT PRODUCT
 APPROVALS FOR WINDOWS AND SHUTTERS. 2014 FBC-B 1609.1.2
 PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS &
 CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE
 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR
 CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31) (B) WINDOWS
 (E) SHUTTERS
  
 4) )SEMI-COMPLIED. UNTIL THE ABOVE COMMENTS ARE
 SATISFIED THE PRESSURES CAN NOT BE VALIDATED. STORM
 SHUTTERS: PROVIDE STORM PANEL INFORMATION WITH
 INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC
 ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT
 GLAZING. FBC 1609.1.2. FL BLD CODE 2010 SECTION
 107.2.5.,1609.1.2, 1715.8 & EXIST BUILD CODE 606.4
 PROCEDURES: A COMPLETE INSTALLATION SCHEDULE
 SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS,
 UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR
 REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT
 TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT
 APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT
 ISSUANCE.
  
 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676