2016-03-16 16:25:20 | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: WED. MARCH 16/ 2016 |
| ACTION: DENIED |
| |
| 1) 2ND REQUEST/ SEMI COMPLIED. THE PERMIT APPLICATION |
| INDICATES THE WORK TO BE PREFORMED UNDER THIS PERMIT IS |
| TO INSTALL A WINDOW AND SHUTTER. THE FLOOR PLAN |
| SUBMITTED INDICATES THERE IS A NEW WINDOW(NON-IMPACT/ |
| NO STORM SHUTTER SUBMITTED FOR THIS OPENING, AND A |
| SHUTTER UNDER FOR A SEPARATE OPENING, WHAT APPEARS TO |
| BE A DOOR ONTO A PATIO. PLEASE PROVIDE THE SIZE OF EACH |
| OF THE OPENINGS (WINDOW AND DOOR) ON THE FLOOR PLAN. |
| THE WINDOW IS THIS A REPLACEMENT SAME SIZE SAME TYPE OF |
| WINDOW? PLEASE NOTE THIS IS NOT A SINGLE FAMILY |
| RESIDENCE BUT A CONDOMINIUM.107.2.1.3 ADDITIONAL |
| INFORMATION IS REQUIRED. |
| |
| 2) THE ENGINEERING EXPRESS SHEET SUBMITTED WILL NEED TO |
| HAVE A ELECTRONIC SIGNATURE TO BE A VALID ENGINEERING |
| SHEET. THE SUBMITTED ENGINEERING SHEET IS FOR THE MORE |
| RESTRICTIVE "D" EXPOSURE WITH ASSOCIATED HIGHER |
| PRESSURES, PLEASE PROVIDE WHAT THE MEAN ROOF HEIGHT OF |
| THIS BUILDING? |
| |
| WIND DESIGN REQUIREMENTS. 2014 FBC-B 1603.1.4 WIND |
| DESIGN DATA. |
| THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE |
| STRUCTURE: |
| |
| 2.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), |
| MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, |
| VASD, AS DETERMINED IN ACCORDANCE WITH SECTION |
| 1609.3.1. |
| |
| 2.2. RISK CATEGORY. |
| |
| 2.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE |
| THAN ONE WIND EXPOSURE IS UTILIZED. |
| |
| 2.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. |
| |
| 2.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR |
| COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY |
| DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL |
| RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ |
| M2). |
| |
| TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & |
| EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| BUILDING. |
| |
| 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. |
| |
| 3)SEMI-COMPLIED. UNTIL THE ABOVE COMMENTS ARE SATISFIED |
| THE PRESSURES CAN NOT BE VALIDATED. SUBMIT PRODUCT |
| APPROVALS FOR WINDOWS AND SHUTTERS. 2014 FBC-B 1609.1.2 |
| PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & |
| CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE |
| 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR |
| CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| APPROVALS: |
| (31) (B) WINDOWS |
| (E) SHUTTERS |
| |
| 4) )SEMI-COMPLIED. UNTIL THE ABOVE COMMENTS ARE |
| SATISFIED THE PRESSURES CAN NOT BE VALIDATED. STORM |
| SHUTTERS: PROVIDE STORM PANEL INFORMATION WITH |
| INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC |
| ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT |
| GLAZING. FBC 1609.1.2. FL BLD CODE 2010 SECTION |
| 107.2.5.,1609.1.2, 1715.8 & EXIST BUILD CODE 606.4 |
| PROCEDURES: A COMPLETE INSTALLATION SCHEDULE |
| SUMMARIZING & IDENTIFYING OPENING SIZES, STORY HEIGHTS, |
| UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR |
| REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT |
| TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT |
| APPLICATION TO FACILITATE PLAN REVIEW AND PERMIT |
| ISSUANCE. |
| |
| 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |