2016-02-10 13:58:14 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) FBC 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS. | | ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE DESIGN. | | | | 2) FBC R308.4.5 REQUIRES SAFETY GLAZING IN THE | | BATHROOM. GLAZING IN WALLS, ENCLOSURES OR FENCES | | CONTAINING OR FACING HOT TUBS, SPAS, WHIRLPOOLS, | | SAUNAS, STEAM ROOMS, BATHTUBS, SHOWERS AND INDOOR OR | | OUTDOOR SWIMMING POOLS WHERE THE BOTTOM EXPOSED EDGE OF | | THE GLAZING IS LESS THAN 60 INCHES (1524 MM) MEASURED | | VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE SHALL | | BE CONSIDERED A HAZARDOUS LOCATION. THIS SHALL APPLY TO | | SINGLE GLAZING AND ALL PANES IN MULTIPLE GLAZING. | | |
|