2016-02-04 08:20:20BUILDING PLAN REVIEW
 W. P. B. REVISION: 16010739
 W. P. B. PERMIT: 15080784
 ADD: 330 CLEMATIS ST. SUITE 110
 CONT: FINELINE CONSTRUCTION
 TEL: 561-582-7880 EXT. 306
 E-MAIL: ??????????
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. FEB. 04/ 2016
 ACTION: DENIED
  
 1) SHEET 1.0A:
 1A) THE FLOOR PLAN SHOWS 138 SEATING SPACES AND ONLY
 ONLY 4 ACCESSIBLE SEATS. PLEASE SHOW COMPLIANCE WITH
 THE 2014 FBC-ACCESSIBILITY CODE.
 138 X 0.05= 6.9 OR 7 SEATING SPACES AT THE DINING
 SURFACES.
  
 1B) PLEASE SHOW COMPLIANCE WITH 2014 FBC-ACCESSIBLITY
 CODE 226.2 DISPERSION. THERE ARE NO ACCESSIBLE SPACES
 SHOWN FOR THE KITCHEN HIGH TOPS OR THE BAR HIGH TOPS.
 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES
 REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED
 THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING
 SURFACES.
  
 2) THE SUBMITTED PRODUCT APPROVAL FOR DATBAR 4080/8080
 STEEL DOORS SHOWS A COMPLIANCE METHOD 9N-3.005(1)(D) AN
 EVALUATION REPORT BY A LICENSED PROFESSIONAL ENGINEER.
 WITHIN THIS DOCUMENT IS A LISST OF TEST REPORTS AND
 REPORT NUMBERS. SINCE THIS IS NOT A FLORIDA APPROVAL OR
 A MIAMI-DADE NOA ,THERE WAS NONE OF THE TEST SUBMITTED
 FROM THE CTLA TESTING LABS TO BACK UP THE ENGINEERING
 LETTER.
  
 THE 2ND ISSUE IS CTLA CERTIFIED TESTING LABS OF ORLANDO
 AN APPROVED TESTING LAB? THERE HAS BEEN NO
 DOCUMENTATION AS OF THIS TESTING LAB.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715