2016-09-28 12:56:08 | NEW SINGLE FAMILY RESIDENCE (R3) FIFTH BUILDING REVIEW |
| CHECKLIST. |
| CODE: FBC 5TH EDITION (2014). |
| |
| |
| NOTE: |
| MISSING ONE SET OF DRAWINGS |
| |
| |
| |
| 1-ENERGY CALCULATIONS SUBMITTED: |
| ORIGINAL COMMENT: |
| A) BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL |
| (EPL) DISPLAY CARD. SEC. R405.3 OF FBC-ENERGY |
| CONSERVATION, 5TH EDITION (2014). |
| |
| RESPONSE: |
| THE INFORMATION IS INCOMPLETE. BUILDER DIDN'T WROTE THE |
| ADDRESS OF THE NEW HOME. |
| |
| ORIGINAL COMMENT: |
| B) THE OWNER OR OWNER'S AUTHORIZED AGENT NEEDS TO |
| CERTIFY AND DATE THE ENERGY CALCULATIONS AT THE BOTTOM |
| OF FORM AS REQUIRED BY SEC. R103.1.1.2 FBC- ENERGY |
| CONSERVATION. ENERGY CALCULATIONS SUBMITTED SHOW THE |
| NAME OF THE OWNER ONLY. THIS IS NOT CERTIFICATION THAT |
| THE OWNER IS COMPLYING WITH THE ENERGY CODE. HE/SHE MAY |
| NOT EVEN BE AWARE OF THIS CERTIFICATION. NEED THE OWNER |
| OR AGENT TO SPECIFICALLY CERTIFY COMPLIANCE. |
| |
| RESPONSE: |
| THE ENERGY CALCULATIONS SUBMITTED NOW ARE DONE BY |
| ANOTHER PERSON. THIS SAME PERSON IS CERTIFYING ON THE |
| OWNER/AGENT LINE. PROVIDE PROOF THAT THE PERSON |
| CERTIFYING CODE COMPLIANCE IS LEGALLY DESIGNATED BY THE |
| OWNER AS REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY |
| CONSERVATION, 5TH EDITION (2014). PERMIT CAN NOT BE |
| ISSUED WITHOUT THE OWNER'S CERTIFICATION. SEC. |
| R103.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| ORIGINAL COMMENT: |
| C) CONDITIONED FLOOR AREA SHOWN ON ITEM #6 WAS REVISED. |
| NOW, IT DOESN'T MATCH FLOOR PLANS. REVISE AS REQUIRED. |
| (NOTE: REVISE THE AREAS SHOWN ON ITEM #8 ACCORDINGLY). |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| NOT ADDRESSED. |
| |
| ORIGINAL COMMENT: |
| D) ROOF MATERIAL SHOWN ON PAGE 2 OF 5 WAS REVISED. NOW |
| IT DOESN'T MATCH MATERIAL SPECIFIED ON PLANS. REVISE AS |
| REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| NOT ADDRESSED. |
| |
| ORIGINAL COMMENT: |
| E) THERE ARE TWO NEW INSULATED DOORS SHOWN ON PAGE 3 OF |
| 5. THERE ARE NOT INSULATED DOORS SPECIFIED ON PLANS OR |
| PRODUCT APPROVALS SUBMITTED. WHERE ARE THESE DOORS. |
| REVISE AS REQUIRED TO MATCH PLANS. SEC. R101.5.1.1.2 |
| FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| NOT ADDRESSED. |
| |
| NOTE: LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR |
| AND SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS |
| WILL BE REQUIRED WHEN THE ENERGY CALCULATIONS ARE NOT |
| USING THE SOFTWARE DEFAULT FACTOR FOR GLAZING. |
| |
| F) ENERGY CALCULATIONS ARE TAKING THE CEILING FAN |
| CREDIT. PREPARER TO PROVIDE COMPLETE DETAILS AND |
| SPECIFICATIONS SHOWING HOW THE HOUSE COMPLIES WITH THE |
| CEILING FAN CREDIT AS REQUIRED BY SEC. R405.7.6 FBC |
| ENERGY CONSERVATION. |
| |
| G) ENERGY CALCULATIONS SHOW AN ATTIC VENT RATIO OF |
| 1/300 ON PAGE 2 OF 5. SEC. R806.2 OF THE |
| FBC-RESIDENTIAL REQUIRES 1/150 RATIO. PREPARER TO |
| PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING HOW |
| THE HOUSE COMPLIES WITH THE 1/300 RATIO AS REQUIRED BY |
| EXCEPTION OF SEC. R806.2 FBC-RESIDENTIAL. |
| |
| |
| ORIGINAL COMMENT: |
| 2- ENERGY CALCULATIONS ARE TAKING THE CEILING FAN AND |
| CROSS VENTILATION CREDITS ON ITEM #15 OF PAGE 1 OF 5. |
| DESIGNER OF RECORD TO PROVIDE COMPLETE DETAILS AND |
| SPECIFICATIONS ON THE CONSTRUCTION DRAWINGS SHOWING |
| FULL COMPLIANCE WITH SEC. R405.7.6 AND SEC. R405.7.4 OF |
| FBC-ENERGY CONSERVATION, 5TH EDITION (2014). |
| |
| RESPONSE: |
| REPEAT COMMENT. NOT ADDRESSED. ENERGY CALCULATIONS ARE |
| STILL TAKING THE CEILING FAN CREDIT. DESIGNER OF RECORD |
| NEEDS TO SHOW IN PLANS COMPLIANCE WITH THE CEILING FAN |
| REQUIREMENTS. PROVIDE ALL THE INFORMATION REQUIRED BY |
| SEC. R405.7.6 FBC-ENERGY CONSERVATION. |
| |
| ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| ***PLEASE REMOVE AND REPLACE ANY REVISED DRAWING. DON'T |
| STAPLE OLD COPY TO THE PLANS. SUBMIT OLD COPIES FOR |
| REFERENCE. |
| |
| IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| (561)805-6712 |
| [email protected] |