Plan Review Notes For Permit 15120507 |
Permit Number |
15120507 |
|
Review Stop |
E |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2015-12-16 16:31:06 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | MARIO VALDES | | ELECTRICAL PLAN EXAMINER | | 516-805-6700 | | [email protected] | | ALTERNATE CONTACT | | MIKE ALBARRAN | | 561-805-6746 | | [email protected] | | | | | | PROVIDE LOAD CALCS | | 215.5 DIAGRAMS OF FEEDERS. IF REQUIRED BY THE AUTHORITY | | HAVING JURISDICTION, A DIAGRAM SHOWING FEEDER DETAILS | | SHALL | | BE PROVIDED PRIOR TO THE INSTALLATION OF THE FEEDERS. | | SUCH A | | DIAGRAM SHALL SHOW THE AREA IN SQUARE FEET OF THE | | BUILDING | | OR OTHER STRUCTURE SUPPLIED BY EACH FEEDER, THE TOTAL | | CALCULATED | | LOAD BEFORE APPLYING DEMAND FACTORS, THE DEMAND FACTORS | | USED, THE CALCULATED LOAD AFTER APPLYING DEMAND | | FACTORS, | | AND THE SIZE AND TYPE OF CONDUCTORS TO BE USED. | | | | SPOKE TO FPL ENGINEER HE STATED ONLY 1 SERVICE DROP AT | | LOT. |
|