Plan Review Notes
Plan Review Notes For Permit 15120203
Permit Number 15120203
Review Stop B
Sequence Number 1
Notes
Date Text
2015-12-15 07:41:53BUILDING PLAN REVIEW
 W. P. B. MASTER: 14071105
 REVISION: 15120203
 ADD: 1517 CAMERON SAMUEL LN.
 CONT: KAST
 TEL: 561-345-4994
 E-MAIL: ?????????????
  
 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
  
 1ST REVIEW
 DATE: TUES. DEC. 15/2015
 ACTION: DENIED
  
 1) CABANA.THE COVERSHEET SHEET A-1 INDICATES THIS
 STRUCTURE WAS DESIGNED TO THE 2014 FBC-B, NOTE THIS WAS
 SUBMITTED AS A REVISION TO THE MASTER. FOR IT TO BE A
 REVISION IT HAS TO HAVE SHEETS ALREADY ON FILE STAMPED
 AND APPROVED. THIS IS NEW WORK AND SHOULD BE UNDER
 SEPERATE PERMIT AND ASSOCIATED FEES. SUBMIT ON THE NEXT
 REVIEW A PERMIT APPLICATION AND ASSOCIATED FEES. THIS
 TRACKING NUMBER CAN BE MADE FROM A REVISION INTO A
 PERMIT. W P B ADMINISTRATIVE CODE 108.2 .
  
 2) CABANA.SHEET A-1 IN INK HAND WRITTEN NOTE THAT A
 ALTERNANTE FOUNDATION FOR CABANA # 1. NO INFORMATION AS
 TO WHO HAS PUT NOTE ON PLANS. PLANS ARE COPRIGHTED ONLY
 THE DESIGNER OF RECORD CAN PUT INK NOTES ON PLANS, THEY
 NEED TO INITIAL AND DATE THE CHANGE. SHEET A1 THE LAST
 REVISION WAS REVISION # 1 DATED 9-14-15.
 FL ADMIN CODE 61G16.003 ARCHITECTS.
  
 2) CABANA. SHEET A-2.0 SHOWS EXTERIOR SLIDING DOORS,
 LOUVERS AND ROOFING PRODUCTS PLEASE PROVIDE COMPLIANCE
 WITH :
 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (C) PANEL WALLS: WALL LOUVERS
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 3) CABANA.107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED
 BY DCA RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. 107.1 GENERAL.
  
 4) CABANA.NOTE THERE IS 2 SETS OF S1 PLANS WITH DETAIL
 1/S-1 BEING DIFFERENT ON BOTH SHEETS. AGAIN THE DETAIL
 THAT SHOWS STEEL HELICAL PILES HAS HAND WRITTEN NOTES,
 NOT SIGNED NOR DATED BY THE ENGINEER OF RECORD.
 61G15-23.001.
  
 5) PLEASE PROVIDE A DETAIL OF AN ACCISSIBLE ENTRANCE
 FOR THE CABANAS FOR THE SLIDING GLASS DOOR TRACK, HOW
 HIGH WILL THE TRACK BE? SHEET A-2 DOES NOT PROVIDE A
 DETAIL SHOWING CODE COMPLIANCE? 2014 FBC-B
 ACCESSIBILITY CODE 404.2.5. THRESHOLDS VERSES
 ACCESSIBLE ENTRANCE.
  
 6) PLEASE SUBMIT GEOTECHNICAL REPORT IN REGAURDS TO THE
 INSTALATION OF THE HELICAL PILE, WHY THE ONE CABANA,
 AND NOT THE OTHERS, QUESTIONABLE SOILS. FBC-B 1803.5.2.
  
 7) RESTROOMS. RESTROOMS WERE PERMITED UNDER PERMIT
 13090634 SITE AMENITIES:
 5.1 POOL RESTROOMS
 5.2 TOWER FEATURE
 5.3 GATE HOUSE
 5.4 DUMPSTER ENCLOSURE
 5.5 MAIL KIOSK.
 THIS PERMIT WAS CLOSED ON 6/16/2014.
 POOL RESTROOMS WILL REQUIRE A SEPEERATE PERMIT FOR
 TRACKING OF INSPECTIONS AND FOR RECORD KEEPING
 PURPOSES. SEPERATE FEES AND REVIEWS WILL BE ASSOCIATED
 WITH THIS PERMIT. NOTE ON THE NEXT SUBMISSION PLEASE
 SUBMIT A PERMIT APPLICATION, AND HAVE A NEW TRACKING
 NUMBER ASSIGNED TO THE POOL RESTROOMS.
 W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT
 FEES, 107.2.1.4 QUALITY OF BUILDING PLANS/ RECORD
 RETENTION.
  
 8) POOL RESTROOMS PLEASE PROVIDE PRODUCT APPROVALS FOR
 RESTROOMS. 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 31)(A) EXTERIOR DOORS. SWING AND ROLL UP
 (C) PANEL WALLS: WALL LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
  
 9) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 10) NEITHER A1 OR A-3 SHOW COMPLIANCE WITH 2014 FBC-B
 1209.2 ATTIC ACCESS.
  
 11) SHEET A-3 RESTROOM GRAB BARS DOES NOT SHOW THE
 HEIGHT OF THE BAR. PLEASE SHOE COMPLIANCE WITH 2014
 FBC-ACCESSIBILITY CODE 609.4. 33-35 INCHES TO THE TOP
 OF THE GRASPABLE SURFACE.
  
 12) DISCREPANACY IN PLANS SHEET S1 VERSES S2. SHEET S1
 NOTE # 13 INDICATES AN ALLOWABLE MINIMUM SAFE BEARING
 VALUE OF 2,000 SPF WHERE AS S2 FOUNDATION NOTES A
 MINIMUM SAFE BEARING VALUE OF 2,500 PSF FROM GEO REPORT
 FROM D&N. 107.2.1.3.
  
 13) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved