Date |
Text |
2016-04-20 09:42:31 | PLUMBING COMMENTS: |
| |
| 1. SHT. A-3 MEN'S RESTROOM SHOWS THE URINALL OFFSET |
| FROM WATER CLOSET AND NEITHER FIXTURE ENCROACHING ON |
| THE CLEAR FLOOR SPACE OF THE OTHER, BUT SHT.P-2 SHOWS |
| THE URINA DIRECTLY IN FRONT OF THE WATER CLOSET WITCH |
| WOULD CAUSE THE WATER CLOSET TO ENCROACH ON THE CLEAR |
| FLOOR SPACE OF THE URINAL SHALL COMPLY WITH FBC ACC. |
| SEC. 604.3.2 |
| PLEASE CLARIFY THE DISCREPANCY'S BETWEEN SHTS. A-3,M-1. |
| E-1,P-2 PER WPB AMEND. TO FBC 107.2.1 |
| |
| 2.SHT. A-0 THE OCCUPANCY GROUP USE IS LISTED AS U. |
| UTILITY AND MISCELLANEOUS GROUP U ARE ACCESSORY |
| BUILDINGS OR STRUCTURES TO MAIN BUILDINGS THAT DO NOT |
| HAVE OR REQUIRE PLUMBING FACILITY'S. THIS IS PART OF A |
| POOL AREA THAT REQUIRES PLUMBING FACILITY'S AND A POOL |
| IS AN A-4 OCCUPANCY. |
| PLEASE CLARIFY PER WPB AMEND. TO FBC SEC. 107.2.1 |
| |
| 3.SHT. A-0 YOU AREA LISTING THE DECK AREA POOL AS 3482 |
| SF IS THIS THE SF OF THE POOL ITSELF OR THE POOL AND |
| DECK AREA COMBINED. |
| PLEASE CLARIFY PER WPB AMEND. TO FBC SEC. 107.2.1 |
| |
| 4. SHT. P-2 YOUR PLUMBING FIXTURE CALCULATIONS APPEAR |
| TO BE BASED ON A POOL SF OF 2500 SF OR LESS SHT. A-0 IS |
| CALLING OUT 3482 SF WITCH WOULD REQUIRE 2 URINALS IN |
| MENS RESTROOM. |
| PLEASE CLARIFY PER WPB AMEND. TO FBC SEC. 107.2.1 |
| |
| 5. PER FBC PL TABLE 403.1 A SERVICE SINK IS REQUIRED |
| FOR A-4 OCCUPANCY'S. |
| |
| 6. YOU SHALL PROVIDE HOT OR TEMPERED WATER TO |
| LAVATORY'S. YOU SHALL PROVIDE HOT WATER TO THE SERVICE |
| SINK. |
| PER FBC PL SEC.607.1 |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE |
| PREVIOUSLY REVIEWED SHEETS. |
| |
| 2ND REVIEW: FBC 2014 |
| |
| GEORGE JOHNSON |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| 561-805-6711 |
| [email protected] |
| |