2015-12-11 17:43:27 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) THE ELECTRICAL PLANS REFERENCE THE 2008 NEC. THE |
| 2011 NEC IS THE EDITION OF NEC THAT IS CURRENTLY |
| REFERENCED BY THE 2014 FBC. |
| |
| 2) THE ELECTRICAL PROVISIONS OF THE 2014 |
| FBC-RESIDENTIAL WILL APPLY TO THIS PROJECT. |
| |
| 3) SHOW COMPLIANCE WITH FBCR-E3901.12 FOR REQUIRED HVAC |
| SERVICE OUTLET RECEPTACLES. |
| |
| 4) SHOW COMPLIANCE WITH FBCR-E3901.7 FOR REQUIRED |
| RECEPTACLE OUTLETS AT FRONT AND REAR OF DWELLING. |
| |
| 5) FBCR-E 3901.2.1 OUTLET SPACING, IT APPEARS SOME |
| POINTS ALONG THE WALL SPACE EXCEED 6' FROM AN OUTLET. |
| |
| 6) NOTE S ON SHEET E3 STATES THAT BEDROOM OUTLETS ARE |
| TO BE AFCI PROTECTED. THE CURRENT ELECTRICAL CODE |
| REQUIRES AFCI PROTECTION FOR RECEPTACLE OUTLETS LOCATED |
| IN OTHER ROOMS AS WELL. SEE FBCR-E3902.12 FOR LIST OF |
| ROOMS THAT REQUIRE AFCI PROTECTION. |
| |
| 7) GARAGE AND OUTDOOR RECEPTACLES ARE REQUIRED TO BE |
| GFCI PROTECTED. FBCR-E 3902 |
| |
| 8) SHOW COMPLIANCE WITH FBCR-E3609.3 FOR REQUIRED |
| INTERSYSTEM BONDING TERMINATION. |
| |
| 9) THE ELECTRICAL RISER DIAGRAM ON SHEET E3 HAS |
| TRANSFER SWITCH ON PANEL B. IS THERE GOING TO BE A |
| FUTURE GENERATOR WITH A TRANSFER SWITCH (SEPARATE |
| PERMIT REQUIRED) INSTALLED TO FEED THIS PANEL FOR |
| EMERGENCY POWER. PLEASE CLARIFY. FBC 107.2.1 |
| |
| |