Date |
Text |
2015-11-19 12:14:00 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL |
| BUILDING PLANS EXAMINER |
| [email protected] |
| 561-805-6724 |
| |
| 1. FBC 107, PROVIDE A GEOTECHNICAL REPORT. BORINGS ARE |
| REQUIRED IN BOTH THE HOUSE AND GARAGE AREAS. REPORT IS |
| TO BE REVIEWED BY DESIGNER OF RECORD PRIOR TO |
| SUBMITTAL. |
| |
| 2. ENGINEERING PREPARED BY RICHARDSON ENGINEERING LACKS |
| A PROJECT ADDRESS/IDENTIFICATION; REVISE, FBC 107. |
| REVISE PLAN TO INCLUDE BASIC INFORMATION - ADDRESS, SF |
| AREA OF PROPOSED STRUCTURE, NUMBER OF STORIES, HEIGHT, |
| FBC 107. |
| |
| 3. PROVIDE A COPY OF THE SURVEY FOR THIS PROPERTY AS |
| WELL AS A SITE PLAN, FBC RES. 302. |
| |
| 4. FOUNDATION DOES NOT MEET THE REQUIREMENT OF FBC RES. |
| 403.1.4, REVISE. |
| |
| 5. AS THIS IS A FOUNDATION PERMIT, REMOVE ITEMS WHICH |
| WILL NOT BE CONSTRUCTED AT THIS TIME. STAIRS ARE SHOWN |
| WITH NO INFORMATION AS WELL AS AN "EXISTING LANDING." |
| THIS SHOULD NOT BE A PART OF THIS FOUNDATION PERMIT. |
| |
| 6. PLAN INCLUDES A LINTEL SCHEDULE, NOT CLEAR WHERE |
| THIS IS APPLICABLE FOR THE SCOPE OF THIS PERMIT, FBC |
| 107. |
| |
| 7. PLAN SHOWS A "NEW DOOR", NOT CLEAR HOW A DOOR COULD |
| BE INSTALLED AT THIS STAGE. |
| |
| 8. "PROPOSED FRAMING PLAN" NOT CLEAR. THIS PLAN SHOULD |
| INCLUDE ONLY STRUCTURAL INFORMATION FOR THE FOUNDATION. |
| LANDING APPEARS TO BE AT THE TOP, IS THIS A ROOF |
| FRAMING PLAN? SECTION 2 SHOWS AN "EXISTING 2ND FLOOR |
| JOIST." PLEASE REMOVE DETAILS WHICH ARE NOT TO BE |
| INCLUDED IN THE SCOPE OF THIS PERMIT. |
| |
| 9. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED, |
| 561-233-5025 FOR MORE INFORMATION. |
| |
| |
| |
| SECTION 1 SPECIFIES "HOLE FOR STRAPS"; PROVIDE A |
| DETAIL. |
| FOUNDATION PLAN SHOWS TRIPLE AND DOUBLE 2X8 BEAMS BUT |
| DOES NOT SPECIFY MATERIAL OR HOW THESE BEAMS WILL BE |
| CONSTRUCTED (FASTENED TOGETHER). |
| PLAN HAS NO INFORMATION REGARDING THE STRUCTURE TO BE |
| RELOCATED OTHER THAN A REFERENCE TO "MOVED HOUSE." |
| SECTIONS 2 AND 3 SHOW 3" COVER, BUT FOOTER STEEL NOT |
| SHOWN OR SPECIFIED. |
| SECTION 1, FOOTING STEEL SHOWN BUT NOT SPECIFIED. |
| |
| 6. IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED. |
| CONTACT 561-233-5025 FOR MORE INFORMATION. |
| |
| 7. ADVISORY ONLY, THIS PERMIT WILL BE ISSUED AT |
| CONTRACTOR'S RISK, SEE FBC 105.13 (PHASED |
| CONSTRUCTION). |
| |
| 8. ADVISORY ONLY, SEPARATE PERMITS ARE REQUIRED FOR |
| PLUMBING, ELECTRICAL, MECHANICAL. |
| |
| **NOTE - CALL MICHELLE, PALM BEACH COUNTY IMPACT FEES, |
| TO CLARIFY SCOPE OF WORK FOR IMPACT FEE ASSESSMENT - |
| 233-5019** |
| |
| |
| |
| |