Plan Review Notes For Permit 15100706 |
Permit Number |
15100706 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2015-10-27 09:44:46 | 1ST REVIEW: FBC 2014 | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | PLUMBING COMMENTS: | | | | | | 1. SHEET E-1 THE PLUMBING RISER DOES NOT SHOW ANY | | FIXTURES MUST SHOW ALL FIXTURES. | | PER WPB AMEND.TO FBC SEC 107.2.1 | | 2.SCOPE OF PLUMBING WORK IS UNCLEAR PLEASE CLEARIFY | | WHAT IS EXISTING WHAT IS NEW AND NEW LOCATIONS IF ANY. | | PER WPB AMEND. TO FBC SEC 107.2.1 | | 3.NEW LOCATION OF WATER HEATER MUSTCOMPLY WITH FPC SEC | | 502.5 CLEARANCES FOR MAINTENANCE AND REPLACEMENT. | | APPLIANCES SHALL BE PROVIDED WITH ACCESS FOR | | INSPECTION, SERVICE, REPAIR AND REPLACEMENT WITHOUT | | DISABLING THE FUNCTION OF A FIRE-RESISTANCE-RATED | | ASSEMBLY OR REMOVING PERMANENT CONSTRUCTION, OTHER | | APPLIANCES OR ANY OTHER PIPING OR DUCTS NOT CONNECTED | | TO THE APPLIANCE BEING INSPECTED, SERVICED, REPAIRED OR | | REPLACED. A LEVEL WORKING SPACE NOT LESS THAN 30 INCHES | | IN LENGTH AND 30 INCHES IN WIDTH (762 MM BY 762 MM) | | SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE TO | | SERVICE AN APPLIANCE. |
|