2015-11-06 15:35:37 | BUILDING PLAN REVIEW |
| W. P. B. PERMIT:15100233 |
| ADD: 428 AVON RD. (PERMIT APP) |
| CONT: DON LIPSCOMB PLUMBING |
| TEL: (561)310-9245 |
| E-MAIL: ??????????????????? |
| |
| 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| FLORIDA BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: FRI. NOV. 06/2015 |
| ACTION: DENIED |
| |
| 1) PLEASE MAKE CORRECTIONS FOR ADDRESSING THE SURVEY BY |
| TARGET, SHEET A.02 INDICATES TWO SEPARATE BUILDINGS ON |
| TWO SEPARATE LOTS AND DIFFERENT PROPERTY CONTROL |
| NUMBERS. |
| THE SURVEY INDICATES BY WAY OF A BUBBLE THE BUILDING |
| LOCATED ON LOT 1480 ADDRESSED 428 AVON RD. |
| |
| THE BUILDING PLANS ARE ADDRESSED 429 AVON AND NEED TO |
| BE CORRECTED, TO 428 AVON RD. THE OTHER ISSUE IN DOING |
| A ADDRESS SEARCH THE PERMIT APPLICATION HAS THE WRONG |
| LOT ON THE PERMIT APPLICATION OF LOT 1487 THE CORRECT |
| LOT NUMBER IS 1480. 107.2.1 INFORMATION ON CONSTRUCTION |
| DOCUMENTS CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK TO BE COMPLETED UNDER THIS PERMIT. |
| |
| 2) THIS PERMIT IS BEING PULLED UNDER A CFC LICENSE, THE |
| SCOPE OF WORK IS BEYOND WHAT A PLUMBING CONTRACTOR CAN |
| DO, F. S. 489.105(M). A BUILDING, ELECTRICAL AND |
| MECHANICAL CONTRACTOR WILL NEED TO SIGN ONTO THIS |
| PROJECT BEFORE IT CAN BE ISSUED. |
| |
| 3) 2014 ENERGY CODE C101.5.1.1 ALTERATIONS, RENOVATIONS |
| AND BUILDING SYSTEMS. ALTERATIONS, RENOVATIONS AND |
| BUILDING SYSTEMS MAY UTILIZE FORM C402. FORM C402 CAN |
| BE FOUND IN APPENDIX C. |
| |
| 4) SHEET A0.4 INDICATES THE NEW RESTROOM DOOR TO BE A |
| 2'-8" DOOR. PLEASE REVIEW 2014 FBC-ACCESSIBLITY CODE |
| 404.2.3 404.2.3 CLEAR WIDTH. DOOR OPENINGS SHALL |
| PROVIDE A CLEAR WIDTH OF 32 INCHES (815 MM) MINIMUM. |
| CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE |
| MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, |
| WITH THE DOOR OPEN 90 DEGREES. OPENINGS MORE THAN 24 |
| INCHES (610 MM) DEEP SHALL PROVIDE A CLEAR OPENING OF |
| 36 INCHES (915 MM) MINIMUM. THERE SHALL BE NO |
| PROJECTIONS INTO THE REQUIRED CLEAR OPENING WIDTH LOWER |
| THAN 34 INCHES (865 MM) ABOVE THE FINISH FLOOR OR |
| GROUND. |
| |
| 5) CHANGE OF OCCUPANCY BUSINESS TO MERCANTILE. BEFORE A |
| PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT FEES MUST BE |
| PAID TO PALM BEACH COUNTY. THE ACTUAL PERMIT SET OF |
| PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY OF THE |
| PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. PLEASE |
| CALL (561)233-5025 FOR MORE INFORMATION. |
| |
| 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| THIS REVIEW. |
| |
| |