2015-11-08 10:00:41 | 1ST REVIEW: FBC 2014 5TH ED. |
| ADMINISTRATIVE REVIEW INTENDED TO PROVIDE DIRECTION TO |
| THE APPLICANT AS TO HOW TO PROCEED. |
| |
| IT APPEARS THE PURPOSE OF THIS APPLICATION IS TO |
| ATTEMPT TO LEGALLY ESTABLISH AN ATTACHED STORAGE ROOM |
| THAT WAS BUILT WITHOUT A PERMIT HOWEVER; THE |
| APPLICATION DESCRIPTION ONLY INDICATES POURING A SLAB |
| AND IS VALUED AT $500.00. THE VALUE IS INCREASED TO |
| $6,020.00 BASED FBC 109.3 AND THE RESULTING INCREASED |
| PERMIT FEES IS TBD AND MUST BE PAID IN FULL PRIOR TO |
| THE REVIEW CONTINUING FURTHER. THE PLANS SHOW CREATING |
| A NEW FOUNDATION AND DO NOT INDICATING THE STRUCTURE |
| ABOVE WAS CONSTRUCTED WITHOUT A PERMIT AND DOES NOT |
| CERTIFY THE WORK IS CODE COMPLIANT, AND DOES NOT |
| SPECIFY MEANS AND METHODS TO ASSURE THE STRUCTURE WILL |
| BE CODE COMPLIANT. MORE DESCRIPTIVE PLANS ARE REQUIRED |
| AS WELL AS AN ENGINEER'S EVALUATION OF ALL THE |
| STRUCTURE WITH IN ORDER TO EVALUATE, AND SPECIFY |
| REQUIRED ENHANCEMENTS AND TO CERTIFY ANY WORK THAT IS |
| COVERED SUCH AS BUT NOT LIMITED TO ALL NAILING, |
| STRAPPING, AND ALL ROOF COVERING COMPONENTS, PRODUCT |
| APPROVAL OF ROOFING, WINDOWS, AND DOORS ARE REQUIRED TO |
| BE SUPPLIED AND REVIEWED BY THE DESIGNER OF RECORD. |
| |
| NOTE: THE OWNER MAY WISH TO CONSIDER DEMOLITION AS AN |
| OPTION FOR THE 140 SF ILLEGALLY ESTABLISHED ADDITION. |
| |
| PLEASE REFERENCE: |
| |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS |
| SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING |
| OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS |
| EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS |
| AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE |
| OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO |
| SECTION 107.3.5). |
| |
| FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR |
| SUBMITTALS. |
| |
| FBC 107.3.5.3 ? INDICATE THE MEANS OF TERMITE |
| PROTECTION PROPOSED PURSUANT TO FBC-R318. |
| |
| GENERAL AFTER THE FACT PERMITS |
| |
| FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A |
| PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY |
| THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK |
| SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION |
| PURPOSES UNTIL APPROVED. |
| |
| FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR |
| TEST REPORTS AS PROOF OF COMPLIANCE. REQUIRED TESTS ARE |
| TO BE MADE AT THE EXPENSE OF THE OWNER, OR AGENT, BY AN |
| APPROVED TESTING LABORATORY OR OTHER APPROVED AGENCY. |
| |
| STEVEN KENNEDY, CBO |
| CHIEF PLANS EXAMINER |
| (561) 805-6710 |
| [email protected] |
| |