Plan Review Notes
Plan Review Notes For Permit 15091257
Permit Number 15091257
Review Stop P
Sequence Number 1
Notes
Date Text
2015-10-05 17:11:561ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
  
  
 PLUMBING COMMENTS:
  
 1. BATHROOM MUST BE A MIN OF 86IN. TO ACCOMIDATE TOILET
 CLEARANCE FOR ACCESSIBILITY. PER FBC ACC. 2014
 604.3.1 SIZE.
 CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 (1525 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES (1420 MM) MINIMUM MEASURED
 PERPENDICULAR FROM THE REAR WALL.
 604.2 LOCATION.
 ADVISORY 604.8.1.1 SIZE.
 THE MINIMUM SPACE REQUIRED IN TOILET COMPARTMENTS IS
 PROVIDED SO THAT A PERSON USING A WHEELCHAIR CAN
 MANEUVER INTO POSITION AT THE WATER CLOSET. THIS SPACE
 CANNOT BE OBSTRUCTED BY BABY CHANGING TABLES OR OTHER
 FIXTURES OR CONVENIENCES, EXCEPT AS SPECIFIED AT
 604.3.2 (OVERLAP). IF TOILET COMPARTMENTS ARE TO BE
 USED TO HOUSE FIXTURES OTHER THAN THOSE ASSOCIATED WITH
 THE WATER CLOSET, THEY MUST BE DESIGNED TO EXCEED THE
 MINIMUM SPACE REQUIREMENTS. CONVENIENCE FIXTURES SUCH
 AS BABY CHANGING TABLES MUST ALSO BE ACCESSIBLE TO
 PEOPLE WITH DISABILITIES AS WELL AS TO OTHER USERS.
 TOILET COMPARTMENTS THAT ARE DESIGNED TO MEET, AND NOT
 EXCEED, THE MINIMUM SPACE REQUIREMENTS MAY NOT PROVIDE
 ADEQUATE SPACE FOR MANEUVERING INTO POSITION AT A BABY
 CHANGING TABLE.
 THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM
 TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR
 PARTITION,
 2. GRAB BARS FOR TOILET SHALL COMPLY WITH FBC ACC.2014
 609.4 POSITION OF GRAB BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE.
 604.5.1 SIDE WALL.
 THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM)
 LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM
 THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM
 FROM THE REAR WALL.
 604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
 3. WATER FAUTAIN SPOUT SHALL COPLY WITH FBC ACC.2014.
 602.5 SPOUT LOCATION.
 THE SPOUT SHALL BE LOCATED 15 INCHES (380 MM) MINIMUM
 FROM THE VERTICAL SUPPORT AND 5 INCHES (125 MM) MAXIMUM
 FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS.
 4.THE SINK IN BREAKROOM SHALL COMPLY WITH FBC ACC. 2014
  
 804.2.2 U-SHAPED.
 IN U-SHAPED KITCHENS ENCLOSED ON THREE CONTIGUOUS
 SIDES, CLEARANCE BETWEEN ALL OPPOSING BASE CABINETS,
 COUNTER TOPS, APPLIANCES, OR WALLS WITHIN KITCHEN WORK
 AREAS SHALL BE 60 INCHES (1525 MM) MINIMUM.
 804.6.1 CLEAR FLOOR OR GROUND SPACE.
 A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 305 SHALL
 BE PROVIDED AT EACH KITCHEN APPLIANCE. CLEAR FLOOR OR
 GROUND SPACES SHALL BE PERMITTED TO OVERLAP.
  
 305.3 SIZE.
 THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30 INCHES (760
 MM) MINIMUM BY 48 INCHES (1220 MM) MINIMUM.
 309.3 HEIGHT.
 OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF
 THE REACH RANGES SPECIFIED IN 308.
  
 308.3.2 OBSTRUCTED HIGH REACH.
 WHERE A CLEAR FLOOR OR GROUND SPACE ALLOWS A PARALLEL
 APPROACH TO AN ELEMENT AND THE HIGH SIDE REACH IS OVER
 AN OBSTRUCTION, THE HEIGHT OF THE OBSTRUCTION SHALL BE
 34 INCHES (865 MM) MAXIMUM AND THE DEPTH OF THE
 OBSTRUCTION SHALL BE 24 INCHES (610 MM) MAXIMUM. THE
 HIGH SIDE REACH SHALL BE 48 INCHES (1220 MM) MAXIMUM
 FOR A REACH DEPTH OF 10 INCHES (255 MM) MAXIMUM. WHERE
 THE REACH DEPTH EXCEEDS 10 INCHES (255 MM), THE HIGH
 SIDE REACH SHALL BE 46 INCHES (1170 MM) MAXIMUM FOR A
 REACH DEPTH OF 24 INCHES (610 MM) MAXIMUM.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved