2015-09-23 17:34:38****CORRECTIONS****
  
 ART LANGE - BUILDING INSPECTOR
 561-805-6667 [email protected]
 FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA
 RESIDENTIAL CODE 2015 5TH EDITION
  
 1. INSUFFICIENT INFORMATION SUBMITTED FOR PLAN REVIEW.
 SUBMIT PLANS SHOWING THE LOCATIONS AND TYPE OF WORK TO
 BE COMPLETED. FOR EXAMPLE, FRAMING DETAILS NOT SHOWN.
 WILL IT BE WOOD OR METAL STUDS AND WHAT GAUGE STUDS.
 STUD SPACING. NOTE: MANY CEMENT BOARD PRODUCT REQUIRE
 16" MAXIMUM STUD SPACING.
  
 2. R-307.2 TILE USED SHALL BE NO LESS THAN 6FT. ABOVE
 THE FLOOR. SHOW ON PLANS.
  
 3. R-307.1 MINIMUM SHOWER MEASUREMENTS ARE 30" IN EACH
 DIRECTION WITH A 24" CLEARANCE IN FRONT OF OPENING.
  
 4. NO ELECTRICAL SHOWN ON PLANS.
  
 5. FBC 1203.4.2.1 VENTILATION REQUIRED.
  
 6. FBC 1207 FLOOR SOUND TRANSMITTION SHALL COMPLY WITH
 THIS SECTION.
  
  
  