Plan Review Notes
Plan Review Notes For Permit 15090399
Permit Number 15090399
Review Stop B
Sequence Number 3
Notes
Date Text
2016-02-16 09:47:33PLAN
 REVIEW COMMENTS
  
 3RD REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE SURVEY SPECIFIES THE PROPERTY AS BEING IN FLOOD
 ZONE B WHEN IT IS ACTUALLY IN FLOOD ZONE C. IF NOT
 CORRECTED, THIS MAY RESULT IN THE HOMEOWNERS PAYING
 MORE FOR FLOOD INSURANCE.
 I DID NOT FIND THE NEW SURVEY THAT WAS REFERENCED IN
 YOUR RESPONSE LETTER IN THE RE-SUBMITTAL. TWO COPIES OF
 THE CORRECTED SURVEY ARE REQUIRED. BECAUSE THESE ARE
 FEE SIMPLE TOWNHOUSES, TWO SETS OF INDIVIDUAL SURVEYS
 FOR EACH LOT ARE REQUIRED FOR EACH UNIT.
  
 2) SHOW COMPLIANCE WITH FBC-R806.1 VENTILATION
 REQUIRED. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES
 FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE
 UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION
 FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS
 PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. SUBMIT
 TWO COPIES OF THE PRODUCT APPROVALS AND MANUFACTURER'S
 SPECIFICATIONS FOR THE 18" DIAMETER INTAKE AND EXHAUST
 ATTIC VENTS ON THE ROOF. PROVIDE INFORMATION TO SHOW
 THAT THEY WILL PROVIDE THE REQUIRED ATTIC VENTILATION.
  
 3) THE PRODUCT APPROVALS WILL BE A PROVISO ITEM TO BE
 SUBMITTED FOR REVIEW AND APPROVAL AT A LATER DATE PRIOR
 TO INSTALLATION AS REQUESTED. FBC 107.3.4 - PROVIDE TWO
 SETS OF PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE
 REGULATED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE
 TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS
 INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN
 PRESSURES FOR EACH OF THE DIFFERENT ROOFING MATERIALS,
 WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND EXTERIOR
 DOOR TYPES (INCLUDING SECTIONAL GARAGE DOORS).
  
 4) THE ENERGY PERFORMANCE EVALUATION FORM CONTAINS
 ERRORS AND IS MISSING INFORMATION. THE FORMS REQUIRE
 THE SIGNATURE OF THE OWNER/AGENT. INDICATE THE CORRECT
 ADDRESS ON THE ENERGY FORM FOR THAT SPECIFIC UNIT.
  
 5) SHEETS 1, 2 AND 5 FROM FRANCIS ENGINEERING ( FIRE
 SPRINKLER PLANS? ) ARE MISSING. A SEPARATE PERMIT,
 APPLICATION AND REVIEW OF FIRE SPRINKLER PLANS ARE
 REQUIRED TO BE SUBMITTED AT A LATER DATE PER YOUR
 REQUEST.
  
 6) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  