2015-12-22 16:37:46 | PLAN |
| REVIEW COMMENTS |
| |
| 2ND REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) THE SURVEY SPECIFIES THE PROPERTY AS BEING IN FLOOD |
| ZONE B WHEN IT IS ACTUALLY IN FLOOD ZONE C. IF NOT |
| CORRECTED, THIS MAY RESULT IN THE HOMEOWNERS PAYING |
| MORE FOR FLOOD INSURANCE. |
| I DID NOT FIND THE NEW SURVEY THAT WAS REFERENCED IN |
| YOUR RESPONSE LETTER IN THE RE-SUBMITTAL. |
| |
| 2) SHOW COMPLIANCE WITH FBC-R806.1 VENTILATION |
| REQUIRED. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES |
| FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE |
| UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION |
| FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS |
| PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. |
| VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION OF |
| 1/16 INCH MINIMUM AND 1/4 INCH MAXIMUM. VENTILATION |
| OPENINGS HAVING A LEAST DIMENSION LARGER THAN 1/4 INCH |
| SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH |
| SCREENING, HARDWARE CLOTH, OR SIMILAR MATERIAL WITH |
| OPENINGS HAVING A LEAST DIMENSION OF 1/16 INCH MINIMUM |
| AND 1/4 INCH MAXIMUM. OPENINGS IN ROOF FRAMING MEMBERS |
| SHALL CONFORM TO THE REQUIREMENTS OF SECTION R802.1.8. |
| REQUIRED VENTILATION OPENINGS SHALL OPEN DIRECTLY TO |
| THE OUTSIDE AIR. CALCULATIONS FOR THE REQUIRED AREA OF |
| VENTILATION OPENINGS WERE ADDED TO THE PLANS. I DID NOT |
| SEE THE LOCATIONS AND SIZES OF THE VENT OPENINGS SHOWN |
| ON THE PLANS. |
| |
| 3) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 |
| THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT |
| APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION |
| INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF |
| THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, |
| STRUCTURAL MULLIONS AND EXTERIOR DOOR TYPES (INCLUDING |
| SECTIONAL GARAGE DOORS). |
| THE FOLLOWING IS A LINK TO THE MIAMI - DADE PRODUCT |
| APPROVAL WEBSITE. |
| HTTP://WWW.MIAMIDADE.GOV/BUILDING/PC-SEARCH_APP.ASP |
| THE FOLLOWING IS A LINK TO THE FLORIDA PRODUCT APPROVAL |
| WEBSITE. |
| HTTPS://FLORIDABUILDING.ORG/PR/PR_APP_SRCH.ASPX |
| |
| 4) THE ENERGY PERFORMANCE EVALUATION FORM CONTAINS |
| ERRORS AND IS MISSING INFORMATION. THE FORMS REQUIRE |
| THE SIGNATURE OF THE OWNER/AGENT. THE STREET IS LAKE |
| AVE. AND NOT LAKE WORTH AVE. THE CITY IS WEST PALM |
| BEACH AND NOT LANTANA. THE JURIDICTION NUMBER IS |
| 604700. THE UNITS DO NOT MEET THE CRITERIA IN FBC |
| ENERGY CONSERVATION SECTION R405.7.4 TO USE THE CROSS |
| VENTILATION OPTION CREDIT. THE FORMS SPECIFY AN |
| UNVENTED ATTIC AND THE PLANS SHOW A VENTILATED ATTIC. |
| THE FORMS SPECIFY A CONCRETE ROOF AND THE PLANS HAVE A |
| PLYWOOD ROOF WITH ASPHALT ROOFING. |
| |
| 5) ACCORDING TO THE DRAWING INDEX ON SHEET CV-1.0, |
| SHEET A-6.0 IS MISSING. SHEETS 1-4 FROM FRANCIS |
| ENGINEERING ( FIRE SPRINKLER PLANS? ) ARE ALSO MISSING. |
| |
| 6) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A |
| RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| COMMENTS HAS BEEN ADDRESSED. |
| |
| 7) THE SIGNATURE OF THE STRUCTURAL ENGINEER APPEARS TO |
| BE A FASCIMILE. FLORIDA STATUTES REQUIRE THAT ALL |
| DRAWINGS AND DOCUMENTS FROM ENGINEERS, AS WELL AS, |
| ARCHITECTS THAT ARE SUBMITTED FOR PUBLIC RECORD HAVE |
| THEIR HANDWRITTEN SIGNATURES ON THEM IN ADDITION TO |
| THEIR SEALS. FAC 61G15-23.002 AND 61G1-16.003 |
| |
| |
| |
| |