2016-04-20 18:13:14 | PLAN |
| REVIEW COMMENTS |
| |
| 2ND REVIEW: FBC FIFTH EDITION (2014) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) (REPEAT COMMENT) FBC 107.3.4 - PROVIDE TWO SETS OF |
| PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH ARE |
| REGULATED BY DCA RULE 9N-3 THAT HAVE BEEN REVIEWED AND |
| APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE |
| TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS |
| INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN |
| PRESSURES FOR EACH OF THE DIFFERENT ROOFING MATERIALS, |
| RIDGE VENT, WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND |
| EXTERIOR DOOR TYPES. THE PRODUCT APPROVALS WERE NOT |
| REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| RECORD. |
| |
| 2) THE PRODUCT APPROVALS FOR THE RIDGE SHINGLE EXPIRED |
| IN 2006. SUBMIT TWO COPIES OF A CURRENT ONE. FBC |
| 107.3.4 |
| |
| 3) THE PLANS SPECIFY DOUBLE HUNG WINDOWS AND THE |
| PRODUCT APPROVALS ARE FOR SINGLE HUNG. FBC 107.2.1 |
| |
| 4) THE DRAWINGS FOR THE FIXED WINDOWS ARE MISSING |
| INFORMATION. THEY WERE NOT SHRUNK DOWN TO FIT ON THE |
| SMALLER SIZE COPY PAPER. FBC 107.2.1 |
| |
| 5) SUBMIT PRODUCT APPROVALS FOR THE ROOF TILE ADHESIVE |
| THAT WILL USED TO INSTALL THE MISSION CLAY TILE. FBC |
| 107.3.4 |
| |
| 6) SUBMIT TWO SETS OF SIGNED AND SEALED RAS 117 |
| CALCULATIONS FOR ENHANCED FASTENING OF THE INSULATION |
| BOARDS AND BASE/ANCHOR SHEET AS REQUIRED BY GENERAL |
| LIMITATION #7 OF THE JOHNS MANVILLE MODIFIED BITUMEN |
| ROOFING SYSTEM (NOA NO. 13-0529.14). |
| |
| 7) THE PRODUCT APPROVALS FOR THE GLAZED FRENCH DOORS |
| THAT WERE SUBMITTED DO NOT CORRESPOND WITH THE DOOR |
| TYPES SHOWN ON SHEET A7.1 OF THE PLANS. FBC 107.2.1 |
| |
| 8) SUBMIT PRODUCT APPROVALS FOR THE SIDE HINGED OUT |
| SWING GARAGE DOORS. FBC 107.3.4 |
| |
| 9) THE STRUCTURAL REPORT FROM THE ENGINEER IS REQUIRED |
| TO HAVE HIS ORIGINAL HANDWRITTEN SIGNATURE ON IT. |
| DIGITALLY SIGNED PLANS ARE ONLY FOR ELECTRONICALLY |
| SUBMITTED DOCUMENTS. FAC 61G15-23.002 & 61G15-23.003 |
| |
| |
| |
| |
| |
| |
| |
| |